Your browser doesn't support javascript.
loading
Estudio comparativo de la eficacia hipotensora y de las variaciones en la amplitud de pulso ocular entre las combinaciones fijas dorzolamida/timolol y brinzolamida/timolol / Comparative study of the pressure lowering efficacy and variations in the ocular pulse amplitude between fixed combinations of dorzolamide/ timolol and brinzolamide/timolol
Sánchez-Pulgarín, M; Martínez-de-la-Casa, J. M; García- Feijoó, J; Sáenz-Francés, F; Santos-Bueso, E; Herrero-Vanrell, R; García Sánchez, J.
Affiliation
  • Sánchez-Pulgarín, M; Hospital Clínico San Carlos. Madrid. España
  • Martínez-de-la-Casa, J. M; Hospital Clínico San Carlos. Madrid. España
  • García- Feijoó, J; Hospital Clínico San Carlos. Madrid. España
  • Sáenz-Francés, F; Hospital Clínico San Carlos. Madrid. España
  • Santos-Bueso, E; Hospital Clínico San Carlos. Madrid. España
  • Herrero-Vanrell, R; Universidad Complutense. Facultad de Farmacia. Madrid. España
  • García Sánchez, J; Hospital Clínico San Carlos. Madrid. España
Arch. Soc. Esp. Oftalmol ; 86(5): 149-153, mayo 2011. graf, tab
Article in Spanish | IBECS | ID: ibc-90529
Responsible library: ES1.1
Localization: BNCS
RESUMEN

Objetivo:

Evaluar las diferencias en cuanto a eficacia hipotensora y amplitud de pulso ocularentre las combinaciones fijas de dorzolamida/timolol y brinzolamida/timolol.

Métodos:

Estudio transversal en 25 sujetos sanos. En cada paciente uno de los ojos fue tratadocon la combinación fija dorzolamida/timolol y el otro con brinzolamida/timolol. La asignaciónfue realizada al azar en cada paciente. Tras la instilación, mediante una escala visualanalógica se evaluaron los posibles efectos adversos (visión borrosa, picor. . .) en cada uno delos ojos. Esta evaluación se repitió a los 30 minutos de la instilación. Mediante un tonómetrode contorno dinámico se registró la presión intraocular y la amplitud de pulso ocular a nivelbasal y a las dos horas de la instilación.

Resultados:

Ambas combinaciones fijas disminuyeron de forma significativa la presión intraoculary la amplitud de pulso ocular sin diferencias significativas entre los dos grupos detratamiento. De los acontecimientos adversos evaluados, el picor fue significativamentemayor en los ojos tratados con dorzolamida/timolol en la primera medida (p = 0,011). Estadiferencia desapareció en la segunda evaluación.

Conclusiones:

Ambas combinaciones fijas demostraron ser igualmente eficaces, produciendovariaciones similares y significativas en la amplitud de pulso ocular. Los efectos adversosfueron en ambos casos leves y bien tolerados presentándose únicamente el picor como másfrecuente en los ojos tratados con dorzolamida/timolol(AU)
ABSTRACT

Objective:

To determine possible differences in the intraocular pressure (IOP) and ocular pulseamplitude (OPA) lowering capacity of the fixed drug combinations dorzolamide/timolol andbrinzolamide/timolol.

Methods:

In this cross-sectional study, one of the eyes of 25 healthy subjects wasrandomly assigned to treatment with dorzolamide/timolol and the other eye with brinzolamide/timolol. After instilling the drops, possible adverse effects (e.g., blurred vision,itching) were assessed in each eye. This assessment was repeated 30 minutes later. IOP andOPA were determined In each eye by dynamic contour tonometry at baseline and two hoursfollowing treatment.

Results:

Both fixed drug combinations significantly reduced IOP and OPA with no differencesdetected between treatment groups. Among the adverse effects recorded, itching wassignificantly greater in the first assessment in the eyes treated with dorzolamide/timolol(P = .011). This difference was no longer apparent in the second assessment.

Conclusions:

Both fixed combinations were similarly effective in reducing intraocular pressureand ocular pulse amplitude. Adverse effects related to both treatments were mild andwell-tolerated, though itching occurred most frequently in the eyes treated with dorzolamide/timolol(AU)
Subject(s)
Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Glaucoma / Ocular Hypertension / Antihypertensive Agents Type of study: Observational study / Prevalence study / Risk factors Limits: Humans Language: Spanish Journal: Arch. Soc. Esp. Oftalmol Year: 2011 Document type: Article Institution/Affiliation country: Hospital Clínico San Carlos/España / Universidad Complutense/España
Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Glaucoma / Ocular Hypertension / Antihypertensive Agents Type of study: Observational study / Prevalence study / Risk factors Limits: Humans Language: Spanish Journal: Arch. Soc. Esp. Oftalmol Year: 2011 Document type: Article Institution/Affiliation country: Hospital Clínico San Carlos/España / Universidad Complutense/España
...