Your browser doesn't support javascript.
loading
Cuál es el mejor FEV1 para detectar insuficiencia respiratoria crónica en la EPOC estable / Below what FEV1 Should Arterial Blood be Routinely Taken to Detect Chronic Respiratory Failure in COPD?
Rodríguez, Diego A; Jover, Lluis; Drakulovic, Mitra B; Gómez, Federico P; Roca, Josep; Barber¨¤, Joan Albert; Wagner, Peter D; Rodríguez-Roisin, Roberto.
Affiliation
  • Rodríguez, Diego A; Hospital Clínic. Servei de Pneumologia (Institut Clinic del Tórax). Barcelona. España
  • Jover, Lluis; Universitat de Barcelona. Department de Salut Pública. Barcelona. España
  • Drakulovic, Mitra B; Hospital Clínic. Servei de Pneumologia (Institut Clinic del Tórax). Barcelona. España
  • Gómez, Federico P; Hospital Clínic. Servei de Pneumologia (Institut Clinic del Tórax). Barcelona. España
  • Roca, Josep; Hospital Clínic. Servei de Pneumologia (Institut Clinic del Tórax). Barcelona. España
  • Barber¨¤, Joan Albert; Hospital Clínic. Servei de Pneumologia (Institut Clinic del Tórax). Barcelona. España
  • Wagner, Peter D; University of California. Division of Physiology. San Diego. Estados Unidos
  • Rodríguez-Roisin, Roberto; Hospital Clínic. Servei de Pneumologia (Institut Clinic del Tórax). Barcelona. España
Arch. bronconeumol. (Ed. impr.) ; 47(7): 325-329, jul. 2011. tab, graf
Article in Spanish | IBECS | ID: ibc-92577
Responsible library: ES1.1
Localization: BNCS
RESUMEN

Introducción:

La gasometría arterial es la medición de elección para el diagnóstico de insuficiencia respiratoria crónica en la enfermedad pulmonar obstructiva crónica (EPOC). Se ha sugerido que el FEV1 se sitúe entre el 30 y el 50% del valor teórico para su indicación, pero estas cifras nunca han sido validadas.

Objetivo:

Identificar los valores de FEV1 post-broncodilatador (BD) y saturación arterial de oxígeno (SaO2) que proporcionen la mejor sensibilidad, especificidad y coeficientes de probabilidad (CP) para el diagnóstico de insuficiencia respiratoria crónica hipoxémica y/o hipercápnica en la EPOC estable.

Métodos:

Se incluyeron 150 pacientes (39 con PaO2 < 60mmHg [8 kPa] y 14 de ellos con una PaCO2¡Ý50mmHg[6,7 kPa]). Se seleccionaron los mejores puntos de corte de FEV1 post-BD y SaO2 para predecirla insuficiencia respiratoria crónica empleando los CP y las curvas Receiver Operating Characteristic.

Resultados:

Un FEV1 post-BD igual al 36% y una SaO2 del 90% fueron los mejores valores predictivos de insuficiencia respiratoria hipoxémica y un FEV1 post-BD igual al 33% para la variante hipercápnica. Un FEV1 ¡Ý45% descartó la insuficiencia respiratoria hipoxémica.

Conclusión:

Un FEV1 post-BD igual al 36% se erige en el mejor punto de corte para predecir adecuadamentetanto la insuficiencia respiratoria hipoxémica como la hipercápnica en el paciente con EPOC estable. Por su parte, una SaO2 del 90% ofrece el mejor valor para la insuficiencia hipoxémica aislada. Estos valores podrían ser considerados para futuras recomendaciones/guías clínicas de la EPOC(AU)
ABSTRACT

Introduction:

To diagnose and assess chronic respiratory failure in stable chronic obstructive pulmonarydisease (COPD) the measurement of arterial blood gases (ABG) is required. It has been suggested that ABGbe determined for this purpose when FEV1 ranges between 50% and 30% predicted, but these thresholdsare not evidence-based.

Objective:

To identify the post-bronchodilator (BD) FEV1 and arterial oxygen saturation (SaO2) valuesthat provide the best sensitivity, specificity, and likelihood ratio (LR) for the diagnosis of hypoxaemicand/or hypercapnic chronic respiratory failure in stable COPD.

Methods:

A total of 150 patients were included (39 with PaO2 < 60mmHg[8 kPa], 14 of them with a PaCO2¡Ý50mmHg[6.7 kPa]). The best post-BD FEV1 and SaO2 cut-off points to predict chronic respiratory failurewere selected using the PC and the Receiver Operating Characteristics (ROC) curves.

Results:

A post-BD FEV1 equal to 36% and an SaO2 of 90% were the best predictive values for hypoxaemicrespiratory failure and a post-BD FEV1 equal to 33% for the hypercapnic variant. An FEV1 ¡Ý45% ruled outhypoxaemic respiratory failure.

Conclusion:

A post-BD FEV1 of 36% is the best cut-off point to adequately predict both hypoxaemic andhypercapnic respiratory failure in the patient with stable COPD. For its part, an SaO2 of 90% is the bestvalue for isolated hypoxaemic failure. These values could be considered for future clinical recommendations/guidelines for COPD(AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Respiratory Insufficiency / Blood Gas Analysis / Oximetry / Forced Expiratory Volume / Pulmonary Disease, Chronic Obstructive Type of study: Diagnostic study / Practice guideline / Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Arch. bronconeumol. (Ed. impr.) Year: 2011 Document type: Article Institution/Affiliation country: Hospital Clínic/España / Universitat de Barcelona/España / University of California/Estados Unidos
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Respiratory Insufficiency / Blood Gas Analysis / Oximetry / Forced Expiratory Volume / Pulmonary Disease, Chronic Obstructive Type of study: Diagnostic study / Practice guideline / Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Arch. bronconeumol. (Ed. impr.) Year: 2011 Document type: Article Institution/Affiliation country: Hospital Clínic/España / Universitat de Barcelona/España / University of California/Estados Unidos
...