Your browser doesn't support javascript.
loading
Registro Español de Marcapasos. VIII Informe Oficial de la Sección de Estimulación Cardiaca de la Sociedad Española de Cardiología (2010) / Spanish Pacemaker Registry. Eighth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2010)
Coma Samartín, Raúl; Sancho-Tello de Carranza, María José; Ruiz Mateas, Francisco; Leal del Ojo González, Juan; Fidalgo Andrés, María Luisa.
Affiliation
  • Coma Samartín, Raúl; Sociedad Española de Cardiología. Madrid. España
  • Sancho-Tello de Carranza, María José; Hospital 12 de Octubre. Madrid. España
  • Ruiz Mateas, Francisco; Hospital Costa del Sol, Marbella. Málaga. España
  • Leal del Ojo González, Juan; Hospital Nuestra Señora de Valme. Sevilla. España
  • Fidalgo Andrés, María Luisa; Complejo Hospitalario de León. León. España
Rev. esp. cardiol. (Ed. impr.) ; 64(12): 1154-1157, dic. 2011. tab, ilus
Article in Spanish | IBECS | ID: ibc-93622
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Introducción y objetivos. En este artículo se describe el análisis de los implantes y recambios de marcapasos remitidos al Registro Español de Marcapasos en 2010, con especial referencia a la selección de los modos de estimulación. Métodos. La recogida de datos se basa en la información de la Tarjeta Europea del Paciente Portador de Marcapasos, que se procesa mediante una aplicación informática específica. Resultados. Se recibió información de 101 centros hospitalarios, con un total de 11.648 tarjetas. Se estima un consumo de 738 generadores por millón de habitantes. Entre los varones hay mayor incidencia de implantes de marcapasos y a una media de edad más baja. El 95,5% de los cables de estimulación utilizados fueron bipolares, el 56% con sistema de fijación activa y el 60% en cavidad auricular. La indicación electrocardiográfica más frecuente es el bloqueo auriculoventricular, seguida de la enfermedad del nódulo sinusal. El 24% de los pacientes con bloqueo auriculoventricular y el 25,6% con enfermedad del nódulo sinusal se estimulan en modo VVI/R (el 12% de unos y otros entre los pacientes de 80 o menos años). Los dispositivos de resincronización cardiaca alcanzan 47 unidades por millón de habitantes; un 25,7% no tiene desfibrilador automático implantable asociado. Conclusiones. Persiste el aumento del consumo de generadores de marcapasos. Los cables de estimulación que se utilizan son bipolares, y en su mayoría son de fijación activa. La edad sigue siendo un factor influyente en la adecuación del modo de estimulación en las diversas afecciones. La elección del modo de estimulación se puede mejorar en más del 20% (AU)
ABSTRACT
Introduction and objectives. Our aim is to describe the analysis of the pacemaker implants and replacements reported to the Spanish Pacemaker Registry in 2010, with special reference to the selection of pacing modes. Methods. Data collection was based on the information provided by the European Pacemaker Patient Identification Card, which was processed using a specially designed computer application. Results. Information was received from 101 hospitals, covering a total of 11 648 cards. An estimated 738 pacemaker generators per million population were placed in 2010. The number of pacemaker implantations is higher and the mean age of the recipients lower among men. Overall, 95.5% of the pacemaker leads used were bipolar, 56% employed an active fixation system, and 60% were placed in atrium. The most common electrocardiographic indication was atrioventricular block, followed by sick sinus syndrome. Twenty-four percent of the patients with atrioventricular block and 25.6% of those with sick sinus syndrome are being paced in VVI/R mode (12% of the patients in each group are aged 80 years or under). Cardiac resynchronization device implantation has reached the level of 47 units per million population, 25.7% of which are not associated with implantable cardioverter defibrillators. Conclusions. The upward trend in the use of pacemaker generators continues. The pacemaker leads used are predominantly bipolar, and the majority are active fixation leads. Age remains a factor in the choice of the appropriate pacing mode for the different types of heart disease. This choice could be improved in more than 20% of the cases of pacemaker implantation (AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Pacemaker, Artificial / Societies, Medical / Cardiac Pacing, Artificial / Annual Reports as Topic Type of study: Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2011 Document type: Article Institution/Affiliation country: Complejo Hospitalario de León/España / Hospital 12 de Octubre/España / Hospital Costa del Sol, Marbella/España / Hospital Nuestra Señora de Valme/España / Sociedad Española de Cardiología/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Pacemaker, Artificial / Societies, Medical / Cardiac Pacing, Artificial / Annual Reports as Topic Type of study: Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2011 Document type: Article Institution/Affiliation country: Complejo Hospitalario de León/España / Hospital 12 de Octubre/España / Hospital Costa del Sol, Marbella/España / Hospital Nuestra Señora de Valme/España / Sociedad Española de Cardiología/España
...