Noise and the quality of sleep in two hospitals in the city of Belo Horizonte, Brazil
Rev. bras. pesqui. méd. biol
; Braz. j. med. biol. res;29(4): 515-20, Apr. 1996. tab
Article
in En
| LILACS
| ID: lil-163896
Responsible library:
BR1.1
ABSTRACT
Male patients of two hospitals in Belo Horizonte completed a questionnaire during an interview on the day of discharge in order to evaluate sleeping conditions related to noise during the previous night and were retested 24 h later. Patients had a worse perception of sleep at the noisier hospital, the University Hospital of the Federal University of Minas Gerais (N = 13), whose internal mean nocturnal noise level was Leq = 53.7 db(A), than at the quieter hospital, Baleia (N = 22), whose internal mean nocturnal noise level was Leq = 45.5 db(A). Noise was the only sleep-disturbing factor which was statistically significant.
Search on Google
Collection:
01-internacional
Database:
LILACS
Main subject:
Sleep
/
Noise
Limits:
Adolescent
/
Adult
/
Humans
/
Male
Country/Region as subject:
America do sul
/
Brasil
Language:
En
Journal:
Braz. j. med. biol. res
/
Rev. bras. pesqui. méd. biol
Journal subject:
BIOLOGIA
/
MEDICINA
Year:
1996
Document type:
Article
/
Congress and conference
Country of publication:
Brazil