Your browser doesn't support javascript.
loading
Validación del método de titulación del virus de la inmunodeficiencia humana tipo 1 / Validation of the titration method for the human immunodeficiency virus type 1
Álvarez Seguí, Giselle; Dubed Echevarría, Marta; Noa Romero, Enrique; Navea Leyva, Leonor M; Pérez Guevara, María T; Rodríguez, Antonio.
Affiliation
  • Álvarez Seguí, Giselle; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Dubed Echevarría, Marta; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Noa Romero, Enrique; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Navea Leyva, Leonor M; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Pérez Guevara, María T; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Rodríguez, Antonio; . Universidad de La Habana.. Facultad de Biología.. Ciudad de La Habana. CU
Rev. cuba. med. trop ; 61(2)May-Aug. 2009.
Article in Spanish | LILACS | ID: lil-584920
Responsible library: BR1.1
RESUMEN

INTRODUCCIÓN:

en la validación de los procesos de producción de productos biológicos, la cuantificación viral es esencial para demostrar su seguridad.

OBJETIVO:

en este trabajo se evaluó el método de titulación del virus de la inmunodeficiencia humana tipo 1, para ello se determinó la exactitud, precisión, linealidad y límite de detección.

MÉTODOS:

la titulación se realizó por el método del cálculo de la dilución punto final, mediante la visualización del efecto citopático y la determinación de la producción de antígeno p24 por medio de un ensayo inmunoenzimático, la dosis infectiva media en cultivo de células por mililitro se calculó según el método de Reed y Muench.

RESULTADOS:

la exactitud del método coincidió con el título de referencia, los valores del coeficiente de variación de la precisión (repetibilidad y precisión intermedia) fueron menores que 5 y 10 por ciento, respectivamente; la linealidad mostró un adecuado coeficiente de correlación y el límite de detección se determinó en la dilución 10-12.

CONCLUSIONES:

el método evaluado demostró un adecuado desempeño para la cuantificación viral.
ABSTRACT

BACKGROUND:

viral quantification is essential to demonstrate biological product safety during the validation of the production process.

OBJECTIVE:

to evaluate the accuracy, linearity and detection limit of a titration method for the human immunodeficiency virus type 1.

METHODS:

the titration was performed by calculating the end-point dilution method, through the cytopathic effect assay and the determination of Ag p24 production by an enzyme immunoassay. Mean infective dose in cultured cells per milimeter was estimated by Reed and Muench´s method.

RESULTS:

the accuracy of the method was similar to that of the reference titration, the variation coefficient figures for accuracy (repeatability and intermediate accuracy) were lower than 5 percent and 10 percent, respectively, the linearity showed adequate correlation coefficient and the detection limit was determined in the 10-12 dilution

CONCLUSIONS:

the evaluated method was suitable for viral quantification.

Full text: Available Collection: International databases Database: LILACS Language: Spanish Journal: Rev. cuba. med. trop Journal subject: Tropical Medicine Year: 2009 Document type: Article Affiliation country: Cuba Institution/Affiliation country: . Universidad de La Habana./CU / Laboratorio de Investigaciones del SIDA/CU
Full text: Available Collection: International databases Database: LILACS Language: Spanish Journal: Rev. cuba. med. trop Journal subject: Tropical Medicine Year: 2009 Document type: Article Affiliation country: Cuba Institution/Affiliation country: . Universidad de La Habana./CU / Laboratorio de Investigaciones del SIDA/CU
...