Repercussão funcional da disfunção endotelial venosa na hipertensão arterial sistêmica: correlação entre função endotelial e complacência venosas e débito cardíaco / Functional repercussion of venous endothelial dysfunction in systemic arterial hypertension: correlation between venous endothelial function and venous compliance and cardiac output
São Paulo; s.n; 2011. [134] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-609388
Responsible library: BR66.1
Localization: BR66.1; W4.DB8, F442re, FM-2, 2011
RESUMO
Enquanto há inúmeros trabalhos evidenciando a participação do território arterial na fisiopatologia da Hipertensão Arterial Sistêmica (HAS), pouco ainda se conhece da real participação do território venoso nessa doença. Estudos prévios demonstraram menor complacência venosa até mesmo em pacientes hipertensos limítrofe, e esta alteração não pode ser explicada como sendo apenas conseqüente a alteração do sistema simpático. Acrescidos a estas alterações, foi demonstrada disfunção endotelial no território venoso em pacientes com fatores de risco cardiovascular, incluindo HAS. Entretanto, ainda existem poucas informações sobre a correlação da disfunção endotelial venosa e/ou da capacitância e complacência venosas e seu impacto funcional na HAS. Neste protocolo foram avaliados 27 indivíduos do Grupo Controle (GC) (idade de 36,8±9,2 anos, 13 homens, IMC de 24,6±4,6 Kg/m2) e 31 pacientes do Grupo Hipertenso (GH) (idade de 38,2±10,5 anos, 15 homens e IMC de 26,1±3,1 Kg/m2). Curvas de pressão arterial (PA) foram obtidas de forma não invasiva com o Finometer®, durante 10 minutos de repouso na posição supina (basal) e durante 10minutos em manobra de modulação de volume (Tilt test). Por meio da análise das curvas, foram calculadas variáveis hemodinâmicas [PA sistólica e diastólica (PAS e PAD), freqüência cardíaca (FC), débito cardíaco (DC), índice cardíaco (CI), índice de volume sistólico (SVI) e índice de resistência vascular periférica (PRI)], além de ser realizada a análise espectral da FC (VFC) e da PAS (VPA). A capacitância e complacência venosas do antebraço foram aferidas por meio da pletismografia e a função endotelial venosa pela técnica da veia dorsal da mão (DHV), ambas avaliadas somente no momento basal.

Resultados:

O padrão hemodinâmico o GH comparado com o GC apresentou maior PAS e PAD no momento basal (p<0,05). Em resposta ao Tilt test, houve aumento de FC (p<0,05), diminuição da PAS (p<0,05), do DC (p<0,05), do CI (p<0,05) e do SVI (p<0,05) em ambos...
ABSTRACT
While there are numerous studies showing the involvement of the arteries in the pathophysiology of systemic arterial hypertension (AH), less is known about the role of the venous system in this disease. Previous studies have demonstrated lower venous compliance in established and borderline hypertensive patients, and this change can not be explained only by an increase in sympathetic activity. It is hypothesized that a lower venous compliance may have an impact on cardiac filling pressures and consequently on blood pressure levels. Furthermore, venous endothelial dysfunction, characterized by a decrease in venous dilation, was detected in patients with AH and with other cardiovascular risk factors. Therefore, we aimed to establish a correlation between venous endothelial dysfunction with venous compliance, and with venous compliance with different hemodynamic parameters. Casuistic and

Methods:

a total of 31 patients with stage 1 and 2 of AH (HG) (age of 38.2 ± 10.5 years, 15 men and BMI of 26.1 ± 3.1 kg/m2) and 27 normotensive subjects the control group (CG) (age 36.8 ± 9.2 years, 13 men, BMI 24.6 ± 4.6 kg/m2) were evaluated. Curves of blood pressure (BP) were obtained non-invasively with Finometer ® device, and were recorded for 10-minute in both supine (baseline) position and during tilt test maneuver. By analyzing the curves, hemodynamic variables [systolic and diastolic BP (SBP and DBP), heart rate (HR), cardiac output (CO), cardiac index (CI), stroke volume index (SVI) and index vascular resistance (IVS)], and spectral analysis of HR (HRV) and SBP (BPV) were performed. The venous capacitance and compliance of the forearm were measured by plethysmography and venous endothelial function by the technique of dorsal hand vein (DHV), both assessed only at baseline.

Results:

At baseline, the HG showed a different hemodynamic pattern compared to the CG, with higher SBP and DBP. In response to the tilt test, both groups presented a similar response...
Subject(s)
Full text: Available Collection: International databases Database: LILACS Main subject: Endothelium, Vascular / Compliance / Hypertension Type of study: Risk factors Limits: Adult / Female / Humans / Male Language: Portuguese Year: 2011 Document type: Thesis