Your browser doesn't support javascript.
loading
Utilidad clínica de la enteroscopia de un solo balón: experiencia de 136 procedimientos en un centro privado de tercer nivel / Clinical usefulness of single balloon enteroscopy: experience of 136 procedures in a third level private hospital
Landaeta, Jorge; Días, Carla; Rodríguez, María; González, Oscar; Casanova, Rosalba; Urdaneta, Clotty.
Affiliation
  • Landaeta, Jorge; s.af
  • Días, Carla; s.af
  • Rodríguez, María; s.af
  • González, Oscar; s.af
  • Casanova, Rosalba; s.af
  • Urdaneta, Clotty; s.af
GEN ; 66(3): 178-181, sep. 2012. ilus, tab
Article in Spanish | LILACS | ID: lil-664541
Responsible library: VE1.1
RESUMEN

Introducción:

La enteroscopia de un solo balón (ESB) es una modalidad de enteroscopia profunda para el diagnóstico y tratamiento de la patología del intestino delgado.

Objetivo:

evaluar la aplicabilidad, seguridad y eficacia de la ESB en pacientes con sospecha de enfermedad del intestino delgado de un centro privado de tercer nivel. Pacientes y

Métodos:

Estudio retrospectivo. Se incluyó todos los pacientes con sospecha de enfermedades del intestino delgado y con indicación de ESB. Se utilizó el enteroscopio Olympus SIF-180Q (200cm de largo, canal de trabajo 2.8mm) acoplado a un sobre tubo de silicón. Se incluyeron 127 pacientes (63 mujeres y 64 hombres) con una media de edad de 50,9 años (7–92 años). Todos los procedimientos (136) fueron realizados bajo sedación asistida por anestesiólogo. Se registraron los datos demográficos, indicaciones, profundidad de inserción, tiempo del procedimiento, hallazgos, terapéutica y complicaciones.

Resultados:

Se realizaron 136 procedimientos (101 abordaje anterógrado, 35 retrógrado) en 127 pacientes (63 mujeres y 64 hombres). La principal indicación fue por hemorragia obscura (43,3%). Otras indicaciones fueron diarrea (20,5%), síndrome anémico (7,1%), obstrucción intestinal parcial (6,3%), entre otros. El tiempo de inserción media, para la vía oral y anal fueron, 39 ± 14 minutos y 40 ± 11 minutos, respectivamente. La longitud media de progresión para la vía anterógrada fue 147 ± 88cm y por vía retrógrada fue de 97 ± 37 cm. El rendimiento diagnóstico se logró en el 70,4% de los casos. El tratamiento endoscópico se realizó en el 43,3%. No se presentaron complicaciones durante o después de los procedimientos.

Conclusión:

La ESB es un método seguro, bien tolerado y altamente eficaz para el estudio de la patología del intestino delgado. La ESB tiene alta sensibilidad diagnóstica y permite frecuentemente la intervención terapéutica...
ABSTRACT

Background:

The single balloon enteroscopy (SBE) is a form of deep enteroscopy for diagnosis and treatment of diseases of the small bowell. The objective is evaluate the applicability, safety and efficacy of SBE in patients with suspected small bowel disease in a private tertiary care center. Patients and

Methods:

a retrospective study. We included all patients with suspected small bowel disease and indicating the SBE. We used the Olympus SIF-180Q enteroscopy (200cm long, 2.8mm working channel) coupled to a silicon overtube. A total of 127 patients were included (63 women and 64 men), mean age of 50.9 years (7 - 92 years). A total of 136 procedures were carried out under sedation assisted by an anesthesiologist. We recorded demographic data, indications, insertion depth, time of procedure, findings, treatment and complications.

Results:

from 136 procedures performed (101 were antegrade approach and 35 were retrograde). The main indication was obscure bleeding (43.3%). Other indications were diarrhea (20.5%), anemic syndrome (7.1%), partial bowel obstruction (6.3%), among others. The average insertion time for the oral and anal were 39 ± 14 minutes and 40 ± 11 minutes, respectively. The average length of progression for the antegrade was 147 ± 88cm and retrograde was 97 ± 37 cm. The diagnostic yield was achieved in 70.4% of cases. Endoscopic treatment was performed in 43.3%. There were no complications during or after all procedures.

Conclusion:

The ESB is a safe, well tolerated and highly effective for study the pathology of the small intestine. The ESB has high diagnostic sensitivity and often allows therapeutic intervention. This retrospective study confirms that ESB is a valuable tool in evaluating small bowel diseases.
Subject(s)

Full text: Available Collection: International databases Health context: Neglected Diseases Health problem: Diarrhea Database: LILACS Main subject: Double-Balloon Enteroscopy / Intestine, Small Type of study: Evaluation study / Observational study Limits: Female / Humans / Male Language: Spanish Journal: GEN Year: 2012 Document type: Article
Full text: Available Collection: International databases Health context: Neglected Diseases Health problem: Diarrhea Database: LILACS Main subject: Double-Balloon Enteroscopy / Intestine, Small Type of study: Evaluation study / Observational study Limits: Female / Humans / Male Language: Spanish Journal: GEN Year: 2012 Document type: Article
...