Acute cardiac rupture during dobutamine-atropine echocardiography stress test.
Orlandini, A D; Tuero, E I; Diaz, R; Vilamajó, O A; Paolasso, E A.
Affiliation
  • Orlandini AD; Instituto Cardiovascular de Rosario, Rosario, Argentina. ecla@satlink.com
J Am Soc Echocardiogr ; 13(2): 152-3, 2000 Feb.
Article in En | MEDLINE | ID: mdl-10668020
We report an acute cardiac rupture during dobutamine-atropine echocardiography stress test on the sixth day after admission for an inferoposterior acute myocardial infarction complicated with mild pericardial effusion.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Atropine / Echocardiography / Dobutamine / Heart Rupture Limits: Humans / Male / Middle aged Language: En Journal: J Am Soc Echocardiogr Journal subject: DIAGNOSTICO POR IMAGEM Year: 2000 Document type: Article Affiliation country: Argentina Country of publication: United States
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Atropine / Echocardiography / Dobutamine / Heart Rupture Limits: Humans / Male / Middle aged Language: En Journal: J Am Soc Echocardiogr Journal subject: DIAGNOSTICO POR IMAGEM Year: 2000 Document type: Article Affiliation country: Argentina Country of publication: United States