End-tidal carbon dioxide levels in the early detection of air embolism.
Anaesth Intensive Care ; 3(1): 58-9, 1975 Feb.
Article in En | MEDLINE | ID: mdl-1130649
Two cases of air embolism in patients anaesthetized in the sitting position are described. The emboli, though producing no signs and therefore probably small, were readily detected by the fall in the end tidal CO2 fraction. Techniques for the detection of air emboli are briefly reviewed.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Respiration / Surgical Procedures, Operative / Carbon Dioxide / Embolism, Air Type of study: Diagnostic_studies / Etiology_studies / Screening_studies Limits: Female / Humans / Male / Middle aged Language: En Journal: Anaesth Intensive Care Year: 1975 Document type: Article Country of publication: United States
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Respiration / Surgical Procedures, Operative / Carbon Dioxide / Embolism, Air Type of study: Diagnostic_studies / Etiology_studies / Screening_studies Limits: Female / Humans / Male / Middle aged Language: En Journal: Anaesth Intensive Care Year: 1975 Document type: Article Country of publication: United States