A pilot study evaluating 99mTc-anti-TNF-alpha scintigraphy in graves' ophtalmopathy patients with different clinical activity score.
Rebelo Pinto, E dos S; Lopes, F P P L; de Souza, S A L; da Fonseca, L M B; Vaisman, M; Gutfilen, B; dos Santos Teixeira, P de F.
Affiliation
  • Rebelo Pinto Edos S; Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil.
Horm Metab Res ; 45(10): 765-8, 2013 Sep.
Article in En | MEDLINE | ID: mdl-23918686
The present study describes the preliminary results of the use of 99mTc-anti-TNF-α scintigraphy as a new diagnostic approach to evaluate patients presenting with Graves' ophthalmopathy (GO). Patients (n=25) presenting at different inflammatory stages of GO and 10 healthy volunteers underwent 99mTc-anti-TNF-α scintigraphy. Images were obtained 15 min after the intravenous injection of 370 MBq (10 mCi) 99mTc-anti-TNF-α. Planar images were obtained in a 256×256 matrix (each lasting 5 min) and single photon emission computed tomography (SPECT) scan lasting 13 min. Regions of interest (ROI) were drawn on the orbit and cerebral hemispheres. The uptake of 99m Tc-anti-TNF-α in these regions was compared and positive scintigraphy established when the ROI was >2.5. In addition, uptake for each positive exam was scored as either slight (2.6-5.1), moderate (5.2-7.6), or high (>7.6). In this pilot study, 69 orbits were evaluated (1 patient had only 1 eye), and 27 had a positive CAS (≥3/7). Scintigraphies were positive in 38 orbits. Comparing the results of the exams with CAS, a high sensitivity and negative predictive values were determined for scintigraphy (96.3% and 96.7%, respectively). However, the specificity and the positive predictive values were 71.4% and 68.4%, respectively, with an accuracy of 81.2%. The exclusion of examinations that were slightly positive from the analysis resulted in an improvement in test accuracy (95.5%). The preliminary results suggest that 99mTc-anti-TNF-α scintigraphy is a promising procedure for the evaluation of active orbital inflammation in GO.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tomography, Emission-Computed, Single-Photon / Technetium / Tumor Necrosis Factor-alpha / Graves Ophthalmopathy / Antibodies Type of study: Clinical_trials / Diagnostic_studies / Prognostic_studies Limits: Adult / Humans / Middle aged Language: En Journal: Horm Metab Res Year: 2013 Document type: Article Affiliation country: Brazil Country of publication: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tomography, Emission-Computed, Single-Photon / Technetium / Tumor Necrosis Factor-alpha / Graves Ophthalmopathy / Antibodies Type of study: Clinical_trials / Diagnostic_studies / Prognostic_studies Limits: Adult / Humans / Middle aged Language: En Journal: Horm Metab Res Year: 2013 Document type: Article Affiliation country: Brazil Country of publication: Germany