Long-term results of clear lens extraction combined with piggyback intraocular lens implantation to correct high hyperopia.
Hua, Xia; Yuan, Xiao-Yong; Song, Hui; Tang, Xin.
Affiliation
  • Hua X; Tianjin Medical University, No.22 Qixiangtai Rd, Tianjin 300070, China ; Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Clinical College of Ophthalmology, Tianjin Medical University, No.4 Gansu Rd, Tianjin 300020, China ; Clinic Barraquer of Ophthalmology, C/Laforja 88, Barcelona 08021, Spain.
Int J Ophthalmol ; 6(5): 650-5, 2013.
Article in En | MEDLINE | ID: mdl-24195042
AIM: To assess the refractive outcome of clear lensectomy combined with piggyback intraocular lens implantation in highly hyperopic patients. METHODS: This case review included 19 eyes of 10 patients with high hyperopia and axial length less than 21mm. Intraocular lens power was calculated for emmetropia using the Holladay II formula in 17 eyes, and SRK/T formula in 2 eyes following clear lens extraction and piggyback intraocular lens implantation. Patients were examined periodically over 24 months for visual acuity and spherical equivalent (SE). RESULTS: The mean postoperative SE at 24 months was 0.20±1.39D (range, -3.00 to 2.50D), better than preoperative 9.81±2.62D (range, +6.00 to +14.50D) (P<0.001). Five eyes had SE within ±0.5D of emmetropia and 11 eyes within ±1.00D at postoperative 24 months. The mean postoperative uncorrected visual acuity (UCVA) at 24 months was 0.60±0.36, significantly improved compared to preoperative 1.39±0.33 (P<0.001). The mean best-corrected visual acuity (BCVA) at 24 months was 0.49±0.35, not statistically different compared to preoperative 0.38±0.30 (P=0.34). Twelve eyes maintained and 1 gained 1 or more Snellen line of BCVA, 4 eyes lost 1 line, and 2 eyes lost 2 lines at 24 postoperative months. Twelve eyes best-corrected near visual acuity (BCNVA) achieved J1 at postoperative 24 months compared to preoperative 7 eyes and the other 7 eyes better than J3. CONCLUSION: Clear lens extraction combined piggyback intraocular lens implantation appears to be an effective procedure to correct high hyperopia but mild overcorrection and intralenticular opacification may require secondary procedure.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Int J Ophthalmol Year: 2013 Document type: Article Affiliation country: Spain Country of publication: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Int J Ophthalmol Year: 2013 Document type: Article Affiliation country: Spain Country of publication: China