Your browser doesn't support javascript.
loading
Cardiac valve calcifications on low-dose unenhanced ungated chest computed tomography: inter-observer and inter-examination reliability, agreement and variability.
van Hamersvelt, Robbert W; Willemink, Martin J; Takx, Richard A P; Eikendal, Anouk L M; Budde, Ricardo P J; Leiner, Tim; Mol, Christian P; Isgum, Ivana; de Jong, Pim A.
Affiliation
  • van Hamersvelt RW; Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, E01.132, 3508 GA, Utrecht, The Netherlands.
Eur Radiol ; 24(7): 1557-64, 2014 Jul.
Article in En | MEDLINE | ID: mdl-24816936
OBJECTIVES: To determine inter-observer and inter-examination variability for aortic valve calcification (AVC) and mitral valve and annulus calcification (MC) in low-dose unenhanced ungated lung cancer screening chest computed tomography (CT). METHODS: We included 578 lung cancer screening trial participants who were examined by CT twice within 3 months to follow indeterminate pulmonary nodules. On these CTs, AVC and MC were measured in cubic millimetres. One hundred CTs were examined by five observers to determine the inter-observer variability. Reliability was assessed by kappa statistics (κ) and intra-class correlation coefficients (ICCs). Variability was expressed as the mean difference ± standard deviation (SD). RESULTS: Inter-examination reliability was excellent for AVC (κ = 0.94, ICC = 0.96) and MC (κ = 0.95, ICC = 0.90). Inter-examination variability was 12.7 ± 118.2 mm(3) for AVC and 31.5 ± 219.2 mm(3) for MC. Inter-observer reliability ranged from κ = 0.68 to κ = 0.92 for AVC and from κ = 0.20 to κ = 0.66 for MC. Inter-observer ICC was 0.94 for AVC and ranged from 0.56 to 0.97 for MC. Inter-observer variability ranged from -30.5 ± 252.0 mm(3) to 84.0 ± 240.5 mm(3) for AVC and from -95.2 ± 210.0 mm(3) to 303.7 ± 501.6 mm(3) for MC. CONCLUSIONS: AVC can be quantified with excellent reliability on ungated unenhanced low-dose chest CT, but manual detection of MC can be subject to substantial inter-observer variability. Lung cancer screening CT may be used for detection and quantification of cardiac valve calcifications. KEY POINTS: • Low-dose unenhanced ungated chest computed tomography can detect cardiac valve calcifications. • However, calcified cardiac valves are not reported by most radiologists. • Inter-observer and inter-examination variability of aortic valve calcifications is sufficient for longitudinal studies. • Volumetric measurement variability of mitral valve and annulus calcifications is substantial.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve / Aortic Valve Stenosis / Calcinosis Type of study: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Eur Radiol Journal subject: RADIOLOGIA Year: 2014 Document type: Article Affiliation country: Netherlands Country of publication: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve / Aortic Valve Stenosis / Calcinosis Type of study: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Eur Radiol Journal subject: RADIOLOGIA Year: 2014 Document type: Article Affiliation country: Netherlands Country of publication: Germany