Your browser doesn't support javascript.
loading
RFE based chondroplasty in wrist arthroscopy indicates high risk for chrondocytes especially for the bipolar application.
Huber, Michaela; Eder, Christoph; Loibl, Markus; Berner, Arne; Zellner, Johannes; Kujat, Richard; Nerlich, Michael; Gehmert, Sebastian.
Affiliation
  • Huber M; Department of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany. michaela1.huber@ukr.de.
  • Eder C; Department of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany. christoph.eder@ukr.de.
  • Loibl M; Department of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany. markus.loibl@ukr.de.
  • Berner A; Department of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany. arne.berner@ukr.de.
  • Zellner J; Department of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany. johannes.zellner@ukr.de.
  • Kujat R; Center for Medical Biotechnology, University of Regensburg, Regensburg, Germany. richard.kujat@ukr.de.
  • Nerlich M; Department of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany. michael.nerlich@ukr.de.
  • Gehmert S; Department of Orthopedic Surgery, University Hospital Basel, Basel, Switzerland. sebastian.gehmert@gmail.com.
BMC Musculoskelet Disord ; 16: 6, 2015 Jan 31.
Article in En | MEDLINE | ID: mdl-25636383
BACKGROUND: The application of radiofrequency energy (RFE) has become widespread for surgical performed chondroplasty especially due to the anticipated sealing effect, however the safety of this procedure in the wrist remains unclear. The purpose of this study was to investigate the subchondral temperature during radiofrequency energy (RFE) application simulating chondroplasty in an arthroscopic setting of the wrist. METHODS: A chondroplasty of the lunate fossa was performed during an arthroscopy setting on 14 cadaver arms using monopolar or bipolar RFE. The temperature was recorded simultaneously from 7 predefined anatomical landmarks. RESULTS: The mean temperature for both application modes did not exceed more than 30°C at all measured points, except for the lunate fossa. The highest subchondral measured peak temperature was 49.35°C (monopolar) and 69.21°C (bipolar) in the lunate fossa. In addition, the temperature decreased for both radiofrequency (RF) devices depending on the distance of the sensors to the RF-probe. CONCLUSION: It remains to be questionable how safe RFE can be used for chondroplasty in wrist arthroscopy under continuous irrigation and constant movement to obtain the desired sealing effect. However, the bipolar device should be applied with more caution since peak temperature in the lunate fossa almost reached 70°C even under continuous irrigation.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroscopy / Wrist Joint / Cartilage, Articular / Catheter Ablation / Chondrocytes Type of study: Etiology_studies / Risk_factors_studies Limits: Humans Language: En Journal: BMC Musculoskelet Disord Journal subject: FISIOLOGIA / ORTOPEDIA Year: 2015 Document type: Article Affiliation country: Germany Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroscopy / Wrist Joint / Cartilage, Articular / Catheter Ablation / Chondrocytes Type of study: Etiology_studies / Risk_factors_studies Limits: Humans Language: En Journal: BMC Musculoskelet Disord Journal subject: FISIOLOGIA / ORTOPEDIA Year: 2015 Document type: Article Affiliation country: Germany Country of publication: United kingdom