Your browser doesn't support javascript.
loading
Theoretical distribution of load in the radius and ulna carpal joint.
Márquez-Florez, Kalenia; Vergara-Amador, Enrique; de Las Casas, Estevam Barbosa; Garzón-Alvarado, Diego A.
Affiliation
  • Márquez-Florez K; Departament of Mechanical and Mechatronics Engineering, Numerical Methods and Modeling Group Research (GNUM), Universidad Nacional de Colombia, Bogotá, Colombia; Biomimetics Laboratory, Instituto de Biotecnología, Universidad Nacional de Colombia, Bogotá, Colombia.
  • Vergara-Amador E; Department of Orthopedic Surgery, School of Medicine, Universidad Nacional de Colombia, Bogotá, Colombia.
  • de Las Casas EB; Department of Structural Engineering, Universidade Federal do Minas Gerais, Belo Horizonte, Brazil.
  • Garzón-Alvarado DA; Departament of Mechanical and Mechatronics Engineering, Numerical Methods and Modeling Group Research (GNUM), Universidad Nacional de Colombia, Bogotá, Colombia; Biomimetics Laboratory, Instituto de Biotecnología, Universidad Nacional de Colombia, Bogotá, Colombia. Electronic address: dagarzona@unal
Comput Biol Med ; 60: 100-6, 2015 May.
Article in En | MEDLINE | ID: mdl-25795995
PURPOSE: The purpose of this study is to validate a model for the analysis of the load distribution through the wrist joint, subjected to forces on the axes of the metacarpals from distal to proximal for two different mesh densities. METHOD: To this end, the Rigid Body Spring Model (RBSM) method was used on a three-dimensional model of the wrist joint, simulating the conditions when making a grip handle. The cartilage and ligaments were simulated as springs acting under compression and tension, respectively, while the bones were considered as rigid bodies. At the proximal end of the ulna the movement was completely restricted, and the radius was allowed to move only in the lateral/medial direction. RESULTS: With these models, we found the load distributions on each carpal articular surface of radius. Additionally, the results show that the percentage of the applied load transmitted through the radius was about 86% for one mesh and 88% for the coarser one; for the ulna it was 21% for one mesh and 18% for the coarser. CONCLUSIONS: The obtained results are comparable with previous outcomes reported in prior studies. The latter allows concluding that, in theory, the methodology can be used to describe the changes in load distribution in the wrist.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radius / Ulna / Carpal Joints Limits: Adult / Humans / Male Language: En Journal: Comput Biol Med Year: 2015 Document type: Article Affiliation country: Colombia Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radius / Ulna / Carpal Joints Limits: Adult / Humans / Male Language: En Journal: Comput Biol Med Year: 2015 Document type: Article Affiliation country: Colombia Country of publication: United States