Your browser doesn't support javascript.
loading
Electrodeposition of reduced graphene oxide on a Pt electrode and its use as amperometric sensor in microchip electrophoresis.
Lucca, Bruno Gabriel; de Lima, Fábio; Coltro, Wendell K T; Ferreira, Valdir Souza.
Affiliation
  • Lucca BG; Instituto de Química, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil.
  • de Lima F; Instituto de Química, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil.
  • Coltro WK; Instituto de Química, Universidade Federal de Goiás, Goiânia, GO, Brazil.
  • Ferreira VS; Instituto de Química, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil.
Electrophoresis ; 36(16): 1886-93, 2015 Aug.
Article in En | MEDLINE | ID: mdl-25884327
This report describes the development and application of a novel graphene-modified electrode to be used as amperometric sensor in microchip electrophoresis (ME) devices. The modified electrode was achieved based on electroreduction of graphene oxide on an integrated Pt working electrode of a commercial ME device. The surface modification was characterized by SEM and cyclic voltammetry techniques. The results indicated that graphene sheets were successfully deposited exhibiting higher surface conductivity and greater electrode sensitivity. The performance of the modified electrode for the amperometric detection on ME devices has been demonstrated by the separation and detection of an anionic mixture containing iodide and ascorbate. The graphene-modified electrode provided significantly higher sensitivity (896.7 vs. 210.9 pA/µM for iodide and 217.8 vs. 127.8 pA/µM for ascorbate), better separation efficiencies (3400 vs. 700 plates/m for iodide and 10 000 vs. 2400 plates/m for ascorbate), enhanced peak resolutions (1.6 vs. 1.0), and LODs (1.5 vs. 5.3 µM for iodide and 3.1 vs. 7.3 µM for ascorbate) in comparison with the unmodified Pt electrode. The proposed amperometric sensor was successfully applied for the analysis of ascorbic acid (through its anionic form) in a commercial medicine sample, and the results achieved were in agreement with the value provided by the supplier. Based on the data here presented, the modified graphene electrode shows great promise for ME applications.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Platinum / Electrophoresis, Microchip / Electrochemical Techniques / Graphite Type of study: Prognostic_studies Language: En Journal: Electrophoresis Year: 2015 Document type: Article Affiliation country: Brazil Country of publication: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Platinum / Electrophoresis, Microchip / Electrochemical Techniques / Graphite Type of study: Prognostic_studies Language: En Journal: Electrophoresis Year: 2015 Document type: Article Affiliation country: Brazil Country of publication: Germany