Your browser doesn't support javascript.
loading
Image-Based Simulations Show Important Flow Fluctuations in a Normal Left Ventricle: What Could be the Implications?
Chnafa, C; Mendez, S; Nicoud, F.
Affiliation
  • Chnafa C; Université de Montpellier - IMAG CNRS UMR 5149, Place Eugene Bataillon, 34095, Montpellier Cedex 5, France. cchnafa@mie.utoronto.ca.
  • Mendez S; Biomedical Simulation Laboratory, University of Toronto - Mechanical and Industrial Engineering, 5 King's College Road, Toronto, ON, M5S 3G8, Canada. cchnafa@mie.utoronto.ca.
  • Nicoud F; Université de Montpellier - IMAG CNRS UMR 5149, Place Eugene Bataillon, 34095, Montpellier Cedex 5, France.
Ann Biomed Eng ; 44(11): 3346-3358, 2016 Nov.
Article in En | MEDLINE | ID: mdl-27073110
Intra-cardiac flow has been explored for decades but there is still no consensus on whether or not healthy left ventricles (LV) may harbour turbulent-like flow despite its potential physiological and clinical relevance. The purpose of this study is to elucidate if a healthy LV could harbour flow instabilities, using image-based computational fluid dynamics (CFD). 35 cardiac cycles were simulated in a patient-specific left heart model obtained from cardiovascular magnetic resonance (CMR). The model includes the valves, atrium, ventricle, papillary muscles and ascending aorta. We computed phase-averaged flow patterns, fluctuating kinetic energy (FKE) and associated frequency components. The LV harbours disturbed flow during diastole with cycle-to-cycle variations. However, phase-averaged velocity fields much resemble those of CMR measurements and usually reported CFD results. The peak FKE value occurs during the E wave deceleration and reaches 25% of the maximum phase-averaged flow kinetic energy. Highest FKE values are predominantly located in the basal region and their frequency content reach more than 200 Hz. This study suggests that high-frequency flow fluctuations in normal LV may be common, implying deficiencies in the hypothesis usually made when computing cardiac flows and highlighting biases when deriving quantities from velocity fields measured with CMR.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Computer Simulation / Ventricular Function, Left / Heart Ventricles / Models, Cardiovascular Limits: Adult / Humans / Male Language: En Journal: Ann Biomed Eng Year: 2016 Document type: Article Affiliation country: France Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Computer Simulation / Ventricular Function, Left / Heart Ventricles / Models, Cardiovascular Limits: Adult / Humans / Male Language: En Journal: Ann Biomed Eng Year: 2016 Document type: Article Affiliation country: France Country of publication: United States