Your browser doesn't support javascript.
loading
Direct analysis of prostaglandin-E2 and -D2 produced in an inflammatory cell reaction and its application for activity screening and potency evaluation using turbulent flow chromatography liquid chromatography-high resolution mass spectrometry.
Shin, Jeong-Sook; Peng, Lei; Kang, Kyungsu; Choi, Yongsoo.
Affiliation
  • Shin JS; Systems Biotechnology Research Center, Korea Institute of Science and Technology (KIST), Gangneung 25451, Republic of Korea.
  • Peng L; Systems Biotechnology Research Center, Korea Institute of Science and Technology (KIST), Gangneung 25451, Republic of Korea; Department of Biological Chemistry, University of Science and Technology, Youseng-gu, Daejeon 305-350, Republic of Korea.
  • Kang K; Systems Biotechnology Research Center, Korea Institute of Science and Technology (KIST), Gangneung 25451, Republic of Korea.
  • Choi Y; Systems Biotechnology Research Center, Korea Institute of Science and Technology (KIST), Gangneung 25451, Republic of Korea; Department of Biological Chemistry, University of Science and Technology, Youseng-gu, Daejeon 305-350, Republic of Korea. Electronic address: yongsoo.choi@kist.re.kr.
J Chromatogr A ; 1463: 128-35, 2016 Sep 09.
Article in En | MEDLINE | ID: mdl-27524299
Direct analysis of prostaglandin-E2 (PGE2) and -D2 (PGD2) produced from a RAW264.7 cell-based reaction was performed by liquid chromatography high-resolution mass spectrometry (LC-HRMS), which was online coupled with turbulent flow chromatography (TFC). The capability of this method to accurately measure PG levels in cell reaction medium containing cytokines or proteins as a reaction byproduct was cross-validated by two conventional methods. Two methods, including an LC-HRMS method after liquid-liquid extraction (LLE) of the sample and a commercial PGE2 enzyme-linked immunosorbent assay (ELISA), showed PGE2 and/or PGD2 levels almost similar to those obtained by TFC LC-HRMS over the reaction time after LPS stimulation. After the cross-validation, significant analytical throughputs, allowing simultaneous screening and potency evaluation of 80 natural products including 60 phytochemicals and 20 natural product extracts for the inhibition of the PGD2 produced in the cell-based inflammatory reaction, were achieved using the TFC LC-HRMS method developed. Among the 60 phytochemicals screened, licochalcone A and formononetin inhibited PGD2 production the most with IC50 values of 126 and 151nM, respectively. For a reference activity, indomethacin and diclofenac were used, measuring IC50 values of 0.64 and 0.21nM, respectively. This method also found a butanol extract of Akebia quinata Decne (AQ) stem as a promising natural product for PGD2 inhibition. Direct and accurate analysis of PGs in the inflammatory cell reaction using the TFC LC-HRMS method developed enables the high-throughput screening and potency evaluation of as many as 320 samples in less than 48h without changing a TFC column.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Mass Spectrometry / Dinoprostone / Prostaglandin D2 / Chromatography, High Pressure Liquid / High-Throughput Screening Assays / Inflammation Type of study: Diagnostic_studies / Screening_studies Limits: Animals Language: En Journal: J Chromatogr A Year: 2016 Document type: Article Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Mass Spectrometry / Dinoprostone / Prostaglandin D2 / Chromatography, High Pressure Liquid / High-Throughput Screening Assays / Inflammation Type of study: Diagnostic_studies / Screening_studies Limits: Animals Language: En Journal: J Chromatogr A Year: 2016 Document type: Article Country of publication: Netherlands