Application of Atmospheric Solids Analysis Probe Mass Spectrometry (ASAP-MS) in Petroleomics: Analysis of Condensed Aromatics Standards, Crude Oil, and Paraffinic Fraction.
Tose, Lilian V; Murgu, Michael; Vaz, Boniek G; Romão, Wanderson.
Affiliation
  • Tose LV; Petroleomic and Forensic Chemistry Laboratory, Department of Chemistry, Federal University of Espírito Santo, 29075-910, Vitória, ES, Brazil.
  • Murgu M; Waters Technologies of Brazil, Alameda Tocantins 125, 27° Andar, Barueri, SP, CEP: 06455-020, Brazil.
  • Vaz BG; Chemistry Institute, Federal University of Goiás, 74001-970, Goiânia, GO, Brazil.
  • Romão W; Petroleomic and Forensic Chemistry Laboratory, Department of Chemistry, Federal University of Espírito Santo, 29075-910, Vitória, ES, Brazil. wandersonromao@gmail.com.
J Am Soc Mass Spectrom ; 28(11): 2401-2407, 2017 11.
Article in En | MEDLINE | ID: mdl-28786095
Atmospheric solids analysis probe mass spectrometry (ASAP-MS) is a powerful tool for analysis of solid and liquid samples. It is an excellent alternative for crude oil analysis without any sample preparation step. Here, ASAP-MS in positive ion mode, ASAP(+)-MS, has been optimized for analysis of condensed aromatics (CA) standards, crude oil, and paraffinic fraction samples using a Synapt G2-S HDMS. Initially, two methodologies were used to access the chemical composition of samples: (1) using a temperature gradient varying from 150 to 600 °C at a heating rate of 150 °C min-1, and (2) with constant temperature of 300 and 400 °C. ASAP(+)-MS ionized many compounds with a typical petroleum profile, showing a greater signals range of m/z 250-1300 and 200-1400 for crude oil and paraffin samples, respectively. Such performance, mainly related to the detection of high molecular weight compounds (>1000 Da), is superior to that of other traditional ionization sources, such as ESI, APCI, DART, and DESI. Additionally, the CA standards were identified in both forms: radicals, [M]+•, and protonated cations, [M + H]+, with minimum fragmentation. Therefore, ASAP was more efficient in accessing the chemical composition of nonpolar and polar compounds. It is promising in its application with ultrahigh resolution MS instruments, such as FT-ICR MS and Orbitrap, since molecular formulas with greater resolution and mass accuracy (<1 ppm) would be assigned. Graphical Abstract ᅟ.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Am Soc Mass Spectrom Year: 2017 Document type: Article Affiliation country: Brazil Country of publication: United States