Your browser doesn't support javascript.
loading
Rapid and accurate assessment of the activity measurements in Brazilian hospitals and clinics.
de Oliveira, A E; Iwahara, A; da Cruz, P A L; da Silva, C J; de Araújo, E B; Mengatti, J; da Silva, R L; Trindade, O L.
Affiliation
  • de Oliveira AE; Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Instituto de Radioproteção e Dosimetria (IRD), Comissão Nacional de Energia Nuclear (CNEN), Av. Salvador Allende, s/n - Barra da Tijuca, CEP - 22783-127 Rio de Janeiro, RJ, Brasil. Electronic address: aedu@ird.gov.br.
  • Iwahara A; Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Instituto de Radioproteção e Dosimetria (IRD), Comissão Nacional de Energia Nuclear (CNEN), Av. Salvador Allende, s/n - Barra da Tijuca, CEP - 22783-127 Rio de Janeiro, RJ, Brasil.
  • da Cruz PAL; Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Instituto de Radioproteção e Dosimetria (IRD), Comissão Nacional de Energia Nuclear (CNEN), Av. Salvador Allende, s/n - Barra da Tijuca, CEP - 22783-127 Rio de Janeiro, RJ, Brasil.
  • da Silva CJ; Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Instituto de Radioproteção e Dosimetria (IRD), Comissão Nacional de Energia Nuclear (CNEN), Av. Salvador Allende, s/n - Barra da Tijuca, CEP - 22783-127 Rio de Janeiro, RJ, Brasil.
  • de Araújo EB; Centro de Radiofarmácia (CERAF), Instituto de Pesquisas Energéticas e Nucleares (IPEN), Comissão Nacional de Energia Nuclear (CNEN), Caixa Postal 11049, CEP 05422-970 São Paulo, Brazil.
  • Mengatti J; Centro de Radiofarmácia (CERAF), Instituto de Pesquisas Energéticas e Nucleares (IPEN), Comissão Nacional de Energia Nuclear (CNEN), Caixa Postal 11049, CEP 05422-970 São Paulo, Brazil.
  • da Silva RL; Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Instituto de Radioproteção e Dosimetria (IRD), Comissão Nacional de Energia Nuclear (CNEN), Av. Salvador Allende, s/n - Barra da Tijuca, CEP - 22783-127 Rio de Janeiro, RJ, Brasil.
  • Trindade OL; Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Instituto de Radioproteção e Dosimetria (IRD), Comissão Nacional de Energia Nuclear (CNEN), Av. Salvador Allende, s/n - Barra da Tijuca, CEP - 22783-127 Rio de Janeiro, RJ, Brasil.
Appl Radiat Isot ; 134: 64-67, 2018 Apr.
Article in En | MEDLINE | ID: mdl-28942991
Traceability in Nuclear Medicine Service (NMS) measurements was checked by the Institute of Radioprotection and Dosimetry (IRD) through the Institute of Energy and Nuclear Research (IPEN). In 2016, IRD ran an intercomparison program and invited Brazilian NMS authorized to administer 131I to patients. Sources of 131I were distributed to 33 NMSs. Three other sources from the same solution were sent to IRD, after measurement at IPEN. These sources were calibrated in the IRD reference system. A correction factor of 1.013 was obtained. Ninety percent of the NMS comparisons results are within ±10% of the National Laboratory of Metrology of Ionizing Radiation (LNMRI) value, the Brazilian legal requirement.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiopharmaceuticals / Ambulatory Care Facilities / Iodine Radioisotopes / Nuclear Medicine Department, Hospital Country/Region as subject: America do sul / Brasil Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2018 Document type: Article Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiopharmaceuticals / Ambulatory Care Facilities / Iodine Radioisotopes / Nuclear Medicine Department, Hospital Country/Region as subject: America do sul / Brasil Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2018 Document type: Article Country of publication: United kingdom