Your browser doesn't support javascript.
loading
Unperturbed, high spatial resolution measurement of Radon-222 in soil-gas depth profile.
Mitev, K; Dutsov, Ch; Georgiev, S; Boshkova, T; Pressyanov, D.
Affiliation
  • Mitev K; Faculty of Physics, Sofia University "St. Kliment Ohridski", Sofia, Bulgaria. Electronic address: kmitev@phys.uni-sofia.bg.
  • Dutsov C; Faculty of Physics, Sofia University "St. Kliment Ohridski", Sofia, Bulgaria.
  • Georgiev S; Faculty of Physics, Sofia University "St. Kliment Ohridski", Sofia, Bulgaria.
  • Boshkova T; Faculty of Physics, Sofia University "St. Kliment Ohridski", Sofia, Bulgaria.
  • Pressyanov D; Faculty of Physics, Sofia University "St. Kliment Ohridski", Sofia, Bulgaria.
J Environ Radioact ; 196: 253-258, 2019 Jan.
Article in En | MEDLINE | ID: mdl-29455912
This work presents a method for measuring the depth distribution of 222Rn activity in soil gas. The method is based on the capacity of polycarbonates to absorb 222Rn and on the possibility of performing sensitive measurements of 222Rn absorbed by the polycarbonates via liquid scintillation counting (LSC). The method is the following: cylindrical holes are drilled along a metal rod and Makrofol® N polycarbonate foils enclosed in polyethylene envelopes are placed in each hole. The rod is driven into the soil and kept for a certain time. As long as the rod is in the soil, the polycarbonate foils are exposed to the 222Rn concentration at their depth. At the end of the exposure the rod is pulled out and the foils are transferred to liquid scintillation (LS) vials filled with liquid scintillator. The 222Rn absorbed in the foils is then measured with a LS analyzer. The rod with the polycarbonate foils acts as a passive probe which senses the 222Rn concentration at different depths beneath the ground surface. The achievable minimum detectable 222Rn activity concentration with the equipment and conditions used in this study is around 12.5 kBq/m3. It can easily be lowered below 1 kBq/m3 if larger foils and low-background LS analyzers are used. Since the method does not require air sampling the depth distribution of 222Rn in the soil is unperturbed by the sampling. The spatial distribution and the maximum measurement depth are set by the distance between the holes and the depth to which the rod can be fixed into the ground. Results from in situ applications of the method in terrains with high 222Rn in soil-gas are reported, which demonstrate the feasibility and the usefulness of the proposed approach.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Soil Pollutants, Radioactive / Radiation Monitoring / Radon Language: En Journal: J Environ Radioact Journal subject: SAUDE AMBIENTAL Year: 2019 Document type: Article Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Soil Pollutants, Radioactive / Radiation Monitoring / Radon Language: En Journal: J Environ Radioact Journal subject: SAUDE AMBIENTAL Year: 2019 Document type: Article Country of publication: United kingdom