Your browser doesn't support javascript.
loading
Ten-Year Results of the Press Fit Condylar Sigma Cobalt-Chrome Total Knee Replacement.
Keenan, Oisin; Brenkel, Ivan; Walmsley, Phil.
Affiliation
  • Keenan O; Department of Orthopaedics and Trauma, Victoria Hospital, Kirkcaldy, Fife, United Kingdom.
  • Brenkel I; Department of Orthopaedics and Trauma, Victoria Hospital, Kirkcaldy, Fife, United Kingdom.
  • Walmsley P; Department of Orthopaedics and Trauma, Victoria Hospital, Kirkcaldy, Fife, United Kingdom.
J Knee Surg ; 32(3): 222-226, 2019 Mar.
Article in En | MEDLINE | ID: mdl-29635648
Total knee arthroplasty (TKA) is reliant on safe and effective implants. The Press Fit Condylar Sigma Cobalt-Chrome (PFCSCC) was introduced in 2006, but no reports have examined long-term failure rates and patient-reported outcome measures (PROMs). The primary aim of this study was to assess survival outcomes of the PFCSCC at 10 years after implantation. Prospective data collection was performed on all patients undergoing primary TKA in one orthopaedic department using this prosthesis exclusively from February 1, 2006, to January 31, 2007. Follow-up was at 10 years. Survival analysis was performed using two primary outcome measures: (1) all-cause joint revision and (2) aseptic revision. Secondary outcomes measures included the American Knee Society Score (AKSS) and Oxford Knee Score (OKS). In total, 249 knees of 233 patients underwent primary TKA. Mean patient age was 66.7 years (range 34-80), and mean body mass index (BMI) was 30 kg/m2 (20.7-40.1). Reviewing all causes of revisions, 14 joints (5.6%) of 14 patients required reoperation. Of these, nine were for deep infection, including six in the first year. Four (1.6%) underwent aseptic revision. Mean AKSS changed from 47.6 to 90.4 (n = 140; p < 0.001) at 10 years, and mean OKS changed from 38.3 to 23.2 (n = 149; p < 0.001). Prospective analysis of consecutive TKA cases using this design of prosthesis demonstrated high survival rates of 94.4% (all-cause revision) and 98.4% (aseptic revision) at 10 years. Postoperative gains in PROMs were sustained at 10 years. These real-world data represent a substantial extension to previous reports for the PFCSCC and suggest that it is not prone to late mechanical failure.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthritis / Arthroplasty, Replacement, Knee / Knee Prosthesis Type of study: Observational_studies / Prognostic_studies Aspects: Patient_preference Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: J Knee Surg Journal subject: ORTOPEDIA Year: 2019 Document type: Article Affiliation country: United kingdom Country of publication: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthritis / Arthroplasty, Replacement, Knee / Knee Prosthesis Type of study: Observational_studies / Prognostic_studies Aspects: Patient_preference Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: J Knee Surg Journal subject: ORTOPEDIA Year: 2019 Document type: Article Affiliation country: United kingdom Country of publication: Germany