Your browser doesn't support javascript.
loading
Precision brackets for upper lateral incisors in Bioprogressive therapy.
Araujo, Alfredo V P; Guedes, Alan B; Cunha, Eriko F A; Frigo, Lucio; Fernandes, Ana P R; Pessoa, Paulo S R; Carvalho, Paulo E G.
Affiliation
  • Araujo AVP; Orthodontics Department, Universidade Cidade de São Paulo (UNICID), São Paulo, Brazil.
  • Guedes AB; Orthodontics Department, Universidade Cidade de São Paulo (UNICID), São Paulo, Brazil.
  • Cunha EFA; Orthodontics Department, Universidade Cidade de São Paulo (UNICID), São Paulo, Brazil.
  • Frigo L; Dental Research Division, Universidade Guarulhos, Guarulhos, São Paulo, Brazil.
  • Fernandes APR; Dental Research Division, Universidade Guarulhos, Guarulhos, São Paulo, Brazil.
  • Pessoa PSR; Dental Research Division, Universidade Guarulhos, Guarulhos, São Paulo, Brazil.
  • Carvalho PEG; Orthodontics Department, Universidade Cidade de São Paulo (UNICID), São Paulo, Brazil.
Microsc Res Tech ; 82(12): 2049-2053, 2019 Dec.
Article in En | MEDLINE | ID: mdl-31587442
Orthodontic brackets, specifically in their slots, are responsible for receiving active orthodontic forces and transferring them to the teeth to be moved. The presence of an altered slot or inaccurate dimensions can influence the mechanical relationship between the bracket and archwire, interfering with the biomechanics of tooth movement. The objective of this study was by comparing the accuracy of slot placement of upper right lateral incisor metal brackets for Bioprogressive Ricketts therapy from five trademarks. The following characteristics were evaluated: height, torque, and internal parallelism of the walls of the slot. The sample included 75 brackets, 15 each from the following trademarks: 3M Abzil, Forestadent, Morelli Rocky Mountain Orthodontics, and Tecnident. Images of the slot profiles were obtained through standardized techniques using scanning electron microscopy, measured by the AutoCAD 2017 software, and compared to Ricketts prescription, respecting standard deviation with the technical and tolerance parameters present in standard ISO 27020. The results indicated that most of the evaluated characteristics were in accordance with the standard parameters, considering the tolerance adopted. There were exceptions found to this pattern of precision in the 3M Abzil brackets with regard to torque variation, and the Morelli brackets in relation to height variation and parallelism between the walls of the slot. Considering the measured dimensional characteristics, the metal brackets used in Bioprogressive Ricketts therapy has satisfactory pattern accuracy; however, there are still some specific inaccuracies in brackets from certain brands that can require more attention during the detailing phase.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Orthodontics / Orthodontic Brackets / Dental Stress Analysis / Incisor Limits: Humans Language: En Journal: Microsc Res Tech Journal subject: DIAGNOSTICO POR IMAGEM Year: 2019 Document type: Article Affiliation country: Brazil Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Orthodontics / Orthodontic Brackets / Dental Stress Analysis / Incisor Limits: Humans Language: En Journal: Microsc Res Tech Journal subject: DIAGNOSTICO POR IMAGEM Year: 2019 Document type: Article Affiliation country: Brazil Country of publication: United States