Your browser doesn't support javascript.
loading
Aptamer-antibody dual probes on single-walled carbon nanotube bridged dielectrode: Comparative analysis on human blood clotting factor.
Yao, Jian; Li, Shujing; Zhang, Liping; Yang, Yuzhi; Gopinath, Subash C B; Lakshmipriya, Thangavel; Zhou, Yawei.
Affiliation
  • Yao J; Emergency Department, The Affiliated Hospital of Qingdao University, Qingdao 266000, PR China.
  • Li S; Department of Radiology, Jinan Central Hospital Affiliated to Shandong University, Jinan, Shandong Province 250013, PR China.
  • Zhang L; Department of Hematology, Dezhou People's Hospital, 1751 Xinhu Road, Dezhou, Shandong Province 253014, PR China.
  • Yang Y; Department of Hematology, Dezhou People's Hospital, 1751 Xinhu Road, Dezhou, Shandong Province 253014, PR China.
  • Gopinath SCB; School of Bioprocess Engineering, Universiti Malaysia Perlis, 02600 Arau, Malaysia; Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia.
  • Lakshmipriya T; Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia.
  • Zhou Y; Department of Hematology, Jinan Central Hospital Affiliated to Shandong University, No. 105, Jiefang Road, Lixia District, Jinan, Shandong Province 250013, PR China. Electronic address: zywhizxyy@sina.com.
Int J Biol Macromol ; 151: 1133-1138, 2020 May 15.
Article in En | MEDLINE | ID: mdl-31743722
Haemophilia is a blood clotting disorder known as 'Christmas disease' caused when the blood has defect with the clotting factor(s). Bleeding leads various issues, such as chronic pain, arthritis and a serious complication during the surgery. Identifying this disease is mandatory to take the necessary treatment and maintains the normal clotting. It has been proved that the level of factor IX (FIX) is lesser with haemophilia patient and the attempt here is focused to quantify FIX level by interdigitated electrode (IDE) sensor. Single-walled carbon nanotube (SWCNT) was utilized to modify IDE sensing surface. On this surface, dual probing was evaluated with aptamer and antibody to bring the possible advantages. The detection limit with antibody was found to be 1 pM, while aptamer shows 100 fM. Further, a fine-tuning was attempted with sandwich pattern of aptamer-FIX-antibody and antibody-FIX-aptamer and compared. Specific elevation of detection with 10 folds was noticed and displayed the detection at 100 f. in both sandwich patterns. In addition, FIX was detected in the diluted human serum by aptamer-FIX-antibody sandwich, it was found that FIX detected from the dilution factor 1:640. A novel demonstration is with higher discrimination against other clotting factors, XI and VII.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Coagulation Tests / Biosensing Techniques / Molecular Probes / Nanotubes, Carbon / Aptamers, Peptide / Antibodies Type of study: Diagnostic_studies / Prognostic_studies Limits: Humans Language: En Journal: Int J Biol Macromol Year: 2020 Document type: Article Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Coagulation Tests / Biosensing Techniques / Molecular Probes / Nanotubes, Carbon / Aptamers, Peptide / Antibodies Type of study: Diagnostic_studies / Prognostic_studies Limits: Humans Language: En Journal: Int J Biol Macromol Year: 2020 Document type: Article Country of publication: Netherlands