Your browser doesn't support javascript.
loading
Determination of the Elemental Composition of Ayahuasca and Assessments Concerning Consumer Safety.
Guimarães, Ivanilce Cristina; Tófoli, Luís Fernando; Sussulini, Alessandra.
Affiliation
  • Guimarães IC; Laboratory of Bioanalytics and Integrated Omics (LaBIOmics), Institute of Chemistry, University of Campinas (UNICAMP), P.O. Box 6154, Campinas, SP, 13083-970, Brazil.
  • Tófoli LF; Interdisciplinary Cooperation for Ayahuasca Research and Outreach (ICARO), School of Medical Sciences, University of Campinas (UNICAMP), Campinas, SP, Brazil.
  • Sussulini A; Laboratory of Bioanalytics and Integrated Omics (LaBIOmics), Institute of Chemistry, University of Campinas (UNICAMP), P.O. Box 6154, Campinas, SP, 13083-970, Brazil. sussulini@iqm.unicamp.br.
Biol Trace Elem Res ; 199(3): 1179-1184, 2021 Mar.
Article in En | MEDLINE | ID: mdl-32504397
The consumption of ayahuasca, a brew prepared from the decoction of two Amazon plants, has increased worldwide in the last decades. This fact raised questions about the safety in its oral administration. In this sense, information concerning the chemical composition of ayahuasca is essential to find a comprehensive reply. Therefore, the aim of this study consisted of determining the elemental composition of ready-to-consume ayahuasca samples produced in Brazil, in order to evaluate the safety in the oral administration of this beverage, considering recommended macroelement and microelement daily intake values and the permitted limits of potentially toxic heavy metals. Real ayahuasca samples, obtained from Brazilian religious groups, underwent microwave radiation-assisted acid decomposition, and Li, Al, Mn, Fe, Co, Cu, Zn, As, Cd, Hg, and Pb concentrations were determined by ICP-MS, while Ca, Mg, K, and P concentrations were determined by ICP OES. Method accuracy was assessed by analyte addition and recovery assays. Recoveries ranged from 80 and 118%, indicating satisfactory accuracy. Limit of detection (LOD) and limit of quantification (LOQ) values were lower than 1 mg L-1 for the macroelements determined by ICP OES and lower than 3.5 µg L-1 for the microelements determined by ICP-MS. The concentrations of the elements determined in the samples were lower than the recommended or tolerable limits; hence, it is possible to affirm that ayahuasca presents safe administration levels regarding total elemental content.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Trace Elements / Banisteriopsis Country/Region as subject: America do sul / Brasil Language: En Journal: Biol Trace Elem Res Year: 2021 Document type: Article Affiliation country: Brazil Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Trace Elements / Banisteriopsis Country/Region as subject: America do sul / Brasil Language: En Journal: Biol Trace Elem Res Year: 2021 Document type: Article Affiliation country: Brazil Country of publication: United States