Risks to children from inhalation of aerosolized aqueous manganese emitted from ultrasonic humidifiers can be greater than for corresponding ingestion.
Water Res
; 207: 117760, 2021 Dec 01.
Article
in En
| MEDLINE
| ID: mdl-34800908
The essential trace element manganese (Mn) can cause neurotoxicity with inhalation acknowledged as a more severe health and cognition threat than ingestion. METHODS: Over a range of aqueous Mn concentrations present in tap water, this research characterizes exposures and risks for adults and 0.25, 1, 2.5, and 6 yr old children who ingest the water and inhale respirable particles produced by a room-sized ultrasonic humidifier filled with the same water. Aqueous Mn concentrations evaluated included 50 µg/L USEPA esthetic guideline, 80 µg/L WHO infant guideline, and 120 µg/L Canadian regulatory level. Airborne-particle-bound Mn concentrations were generated for water filling an ultrasonic humidifier under four realistic room conditions (33 m3 small or 72 m3 large) with varying ventilation rates from 0.2/h -1.5/h. Average daily doses (ADD) and reference intake doses were calculated for ingestion and 8-h inhalation of humidified air. Hazard quotients (HQ) compared the intake doses and reference doses. Multi-path particle dosimetry (MPPD) model quantified the particle deposition and deposited dose in children's and adults' respiratory tracts. RESULTS: At only 11 µg/L Mn, the resulting humidified air Mn exceeds USEPA's reference concentration of 0.05 µg/m3 Mn in small room with low, energy-efficient ventilation. Inhalation ADD are 2 magnitudes lower than ingestion ADD for identical water Mn concentrations and daily exposure frequency. Even so, ingestion HQs are approximately 0.2 but inhalation risk is significant (HQ>1) for children and adults when breathing Mn-humidified air under most small room conditions at 50, 80 or 120 µg/L Mn. MPPD model indicates inhaled Mn deposits in head and pulmonary regions, with greater Mn dose deposits in children than adults. CONCLUSION: Inhalation of Mn-particles produced from ultrasonic humidifiers can pose greater risks than ingestion at the same water concentration, especially for children. Aqueous Mn concentration and room size influence risks. Limiting manganese exposures and setting regulations requires consideration of both ingestion and inhalation of water.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Humidifiers
/
Manganese
Type of study:
Etiology_studies
/
Risk_factors_studies
Limits:
Adult
/
Child
/
Humans
/
Infant
Country/Region as subject:
America do norte
Language:
En
Journal:
Water Res
Year:
2021
Document type:
Article
Affiliation country:
United States
Country of publication:
United kingdom