Your browser doesn't support javascript.
loading
Porous layer open tubular nano liquid chromatography directly coupled to electron ionization mass spectrometry.
Vargas Medina, Deyber Arley; Burato, Juliana Soares da Silva; Borsatto, João Victor Basolli; Lanças, Fernando Mauro.
Affiliation
  • Vargas Medina DA; Institute of Chemistry at São Carlos (IQSC), University of São Paulo, São Carlos, SP 13560-970, Brazil.
  • Burato JSDS; Institute of Chemistry at São Carlos (IQSC), University of São Paulo, São Carlos, SP 13560-970, Brazil.
  • Borsatto JVB; Institute of Chemistry at São Carlos (IQSC), University of São Paulo, São Carlos, SP 13560-970, Brazil.
  • Lanças FM; Institute of Chemistry at São Carlos (IQSC), University of São Paulo, São Carlos, SP 13560-970, Brazil. Electronic address: flancas@iqsc.usp.br.
J Chromatogr A ; 1674: 463143, 2022 Jul 05.
Article in En | MEDLINE | ID: mdl-35588591
A 25 µm i.d x 1.2 m length PS-DVB porous layer open tubular column (PLOT) was prepared and assessed in the configuration of a nano liquid chromatography coupled to an electron ionization mass spectrometry system (OT-nanoLC-EI-Ms), via the direct insertion of the column outlet into the ionization source. The developed system's operational parameters were comprehensively studied, and the setup performance was investigated employing both unidimensional and column switching configurations. As a result, the OT-nanoLC-EI-MS system demonstrated competitive applicability in separating non-amenable ESI compounds, such as polyaromatic hydrocarbons (PAHs) and non-amenable GC compounds such as thermolabile pesticides. Furthermore, with excellent chromatographic performance, the PLOT columns can work under more compatible EI-detection conditions - such as the elution with 100% organic solvent. For example, PAHs retention factors ranged between 1.5 and 2.2 for 100% MeCN mobile phase, and more than 33,000 plates per meter for naphthalene at 50 nL/min flow rate. In analyzing thermolabile pesticides, the column switching PLOT-nanoLC-EI-MS system provided LODs of 25 µg/L, demonstrating suitable intra e interday reproducibility (% RSD < 13%, n = 3), and possibilities the direct injection of raw samples with suitable robustness.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pesticides / Spectrometry, Mass, Electrospray Ionization Language: En Journal: J Chromatogr A Year: 2022 Document type: Article Affiliation country: Brazil Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pesticides / Spectrometry, Mass, Electrospray Ionization Language: En Journal: J Chromatogr A Year: 2022 Document type: Article Affiliation country: Brazil Country of publication: Netherlands