Your browser doesn't support javascript.
loading
Design of an electrochemical aptasensor in the presence of an array of gold nanostructure and a GO-MWCNTs nanocomposite: application in diagnosis of Alzheimer's disease.
Negahdary, Masoud; Buoro, Rafael Martos; Bacil, Raphael Prata; Santos, Berlane Gomes; Angnes, Lúcio.
Affiliation
  • Negahdary M; Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo, 05508-000, Brazil. mnegahdary@iq.usp.br.
  • Buoro RM; Institute of Chemistry of São Carlos, University of São Paulo, Av. Trabalhador São-Carlense, 400, São Carlos, 13556-590, Brazil.
  • Bacil RP; Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo, 05508-000, Brazil.
  • Santos BG; Instituto de Química, Universidade Estadual de Campinas-UNICAMP-Rua Josué de Castro, 126, Cidade Universitária, Campinas, SP, CEP 13083-861, Brazil.
  • Angnes L; Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo, 05508-000, Brazil.
Mikrochim Acta ; 190(10): 409, 2023 09 21.
Article in En | MEDLINE | ID: mdl-37733170
Alzheimer's disease (AD) is considered one of the main progressive chronic diseases in elderly individuals. Early diagnosis using related biomarkers, specifically beta-amyloid peptide (Aß), allows finding expected treatment routes. Here, we developed an electrochemical aptasensing platform for AD by employing a glassy carbon electrode (GCE) modified with a layer of jagged gold (JG) nanostructure (diameter: 60-185 nm) and graphene oxide-carboxylic acid functionalized multiwalled carbon nanotubes (GO-c-MWCNTs) nanocomposite. These surface modifications acted as the signal amplifier and provided an optimum nano-interface substrate for immobilizing aptamer strands. The measurements of Aß were performed via differential pulse voltammetry (DPV), and the aptasensor detected the analyte in a linear range from 0.1 pg mL-1 to 1 ng mL-1, with an estimated limit of detection (LOD) of about 0.088 pg mL-1 (S/N = 3). The aptasensor showed sufficient stability (11 days), reversibility (three times), and reproducibility (five times re-fabrication with relative standard deviation (RSD): 1.27). The potential interfering agents showed negligible impact on the sensing performance. Finally, the application of the aptasensor was evaluated in the presence of 10 serum samples, and the recovery values were from 93 to 110.1%.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Nanotubes, Carbon / Nanocomposites / Alzheimer Disease Type of study: Diagnostic_studies / Screening_studies Limits: Aged / Humans Language: En Journal: Mikrochim Acta Year: 2023 Document type: Article Affiliation country: Brazil Country of publication: Austria

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Nanotubes, Carbon / Nanocomposites / Alzheimer Disease Type of study: Diagnostic_studies / Screening_studies Limits: Aged / Humans Language: En Journal: Mikrochim Acta Year: 2023 Document type: Article Affiliation country: Brazil Country of publication: Austria