Nanofibrous composite from chitosan-casein polyelectrolyte complex for rapid hemostasis in rat models in vivo.
Mishra, Balaram; Pathak, Devendra; Verma, Devendra; Gupta, Mukesh Kumar.
Affiliation
  • Mishra B; Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Odisha 769008, India.
  • Pathak D; Department of Veterinary Anatomy, College of Veterinary Science, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, Punjab 140004, India.
  • Verma D; Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Odisha 769008, India.
  • Gupta MK; Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Odisha 769008, India; National Animal Resource Facility for Biomedical Research (NARFBR), Indian Council of Medical Research, Genome Valley, Telengana 500078, India. Electronic address: guptam@nitrkl.ac.i
Int J Biol Macromol ; 269(Pt 1): 131882, 2024 Jun.
Article in En | MEDLINE | ID: mdl-38677684
ABSTRACT
Bleeding causes ∼5.8 million deaths globally; half of the patients die if rapid hemostasis is not achieved. Here, we report a chitosan-casein (CC)-based nanofibrous polyelectrolyte complex (PEC) that could clot blood within 10 s in the rat femoral artery model in vivo. The nanofiber formation by self-assembly was also optimized for process parameters (concentration, mixing ratio, pH, and ultrasonication). Results showed that increasing the concentration of chitosan from 10 % to 90 % in the formulation increased the productivity (r = 0.99) of PECs but led to increased blood clotting time (r = 0.90) due to an increase in zeta potential (r = 0.98), fiber diameter (r = 0.93), and decreased surface porosity (r = -0.99), absorption capacity (r = -0.99). The pH also influenced the zeta potential of PEC, with an optimized pH of 8.0 ± 0.1 yielding clear nanofibers. Sonication improved the segregation of nanofibers by promoting water removal. The optimized PECs containing chitosan and casein in the ratio of 3070 (CC30) at a pH of 8.0 and dehydration under sonication could clot the blood within 9 ± 2 s in vitro and 9 ± 2 s in rat femoral artery puncture model. The CC30 formulation did not cause any irritation or corrosion on rat skin. Histopathology and immunohistochemistry of various organs showed that CC30 was biocompatible and non-immunogenic under in vivo conditions.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Caseins / Chitosan / Nanofibers / Polyelectrolytes / Hemostasis Limits: Animals Language: En Journal: Int J Biol Macromol Year: 2024 Document type: Article Affiliation country: India Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Caseins / Chitosan / Nanofibers / Polyelectrolytes / Hemostasis Limits: Animals Language: En Journal: Int J Biol Macromol Year: 2024 Document type: Article Affiliation country: India Country of publication: Netherlands