Your browser doesn't support javascript.
loading
Left atrial appendage thrombus is associated with a higher fractal dimension in patients with atrial fibrillation.
Jing, Mengyuan; Xi, Huaze; Li, Jianying; Liu, Qing; Zhu, Hao; Sun, Qiu; Zhang, Yuting; Liu, Xuehui; Ren, Wei; Zhang, Bin; Deng, Liangna; Han, Tao; Zhou, Junlin.
Affiliation
  • Jing M; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Xi H; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Li J; GE Healthcare, Computed Tomography Research Center, Beijing, China.
  • Liu Q; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Zhu H; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Sun Q; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Zhang Y; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Liu X; Ultrasound Medical Center, Lanzhou University Second Hospital, Lanzhou, China.
  • Ren W; GE Healthcare, Computed Tomography Research Center, Beijing, China.
  • Zhang B; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Deng L; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Han T; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
  • Zhou J; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, China; Second Clinical School, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificia
Clin Imaging ; 114: 110247, 2024 Oct.
Article in En | MEDLINE | ID: mdl-39146827
ABSTRACT

PURPOSE:

To assess the anatomical complexity of the left atrial appendage (LAA) using fractal dimension (FD) based on cardiac computed tomography angiography (CTA) and the association between LAA FD and LAA thrombosis. MATERIALS AND

METHODS:

Patients with atrial fibrillation (AF) who underwent both cardiac CTA and transesophageal echocardiography (TEE) between December 2018 and December 2022 were retrospectively analyzed. Patients were categorized into normal (n = 925), circulatory stasis (n = 82), and thrombus groups (n = 76) based on TEE results and propensity score matching (PSM) was performed for subsequent analysis. FD was calculated to quantify the morphological heterogeneity of LAA. Independent risk factors for thrombus were screened using logistic regression. The diagnostic performance of FD and CHA2DS2-VaSc score for predicting thrombus was evaluated using the area under the receiver operating characteristics curve (AUC).

RESULTS:

LAA FD was higher in the thrombus group (1.61 [1.49, 1.70], P < 0.001) than in the circulatory stasis (1.33 [1.18, 1.47]) and normal groups (1.30 [1.18, 1.42]) both before and after PSM. LAA FD was also an independent risk factor in the thrombus (OR [odds ratio] = 570,861.15 compared to normal, 41,122.87 compared to circulatory stasis; all P < 0.001) and circulatory stasis group (OR = 98.87, P = 0.001) after PSM. The diagnostic performance of LAA FD was significantly better than the CHA2DS2-VaSc score in identifying thrombus.

CONCLUSIONS:

Patients with high LAA FD are more likely to develop LAA thrombus, and the use of FD provides an effective method for assessing the risk of thrombosis in AF patients, thereby guiding individualized clinical treatment.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Atrial Fibrillation / Thrombosis / Fractals / Echocardiography, Transesophageal / Atrial Appendage Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Clin Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2024 Document type: Article Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Atrial Fibrillation / Thrombosis / Fractals / Echocardiography, Transesophageal / Atrial Appendage Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Clin Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2024 Document type: Article Country of publication: United States