Your browser doesn't support javascript.
loading
Dual Ambient Sampling Hollow Cathode Discharge Ionization-Mass Spectrometry System: An Approach for Detecting Explosives and Drugs of Abuse at Trace to Ultratrace Levels.
Shi, Lulu; Habib, Ahsan; Bi, Lei; Wen, Luhong.
Affiliation
  • Shi L; Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, Shanghai China.
  • Habib A; The Research Institute of Advanced Technologies, Ningbo University, Ningbo 315211, Zhejiang China.
  • Bi L; China Innovation Instrument Co., Ltd., Ningbo 315000, Zhejiang China.
  • Wen L; The Research Institute of Advanced Technologies, Ningbo University, Ningbo 315211, Zhejiang China.
J Am Soc Mass Spectrom ; 35(9): 2209-2221, 2024 Sep 04.
Article in En | MEDLINE | ID: mdl-39164201
ABSTRACT
Detection of illicit compounds like explosives and drugs of abuse at trace levels is crucial to provide public security and health safety. A dual ambient sampling system hollow cathode discharge (HCD) ion source was developed to investigate its performance. Here, trinitrotoluene (TNT), trinitrobenzene (TNB), hexamethylene triperoxide diamine (HMTD), and triacetone triperoxide (TATP) as explosives and methamphetamine (MA) as drugs of abuse were taken as model compounds. Two sample inlets, inlet-1 and inlet-2, are available for ambient sampling. In negative ion mode, N2 and air HCD plasmas are confined close to inlet-1, but in positive ion mode, they are confined close to inlet-2. Special design of the ion source makes it feasible to generate multiple ions from a single analyte, which assists in understanding the gas phase ionization mechanism. In negative ion mode, both TNT and TNB gave radical ions, [M]-•, as major ions for N2 HCD plasma as they were introduced via inlet-1 or inlet-2. TNB gave radical ions for air and N2 HCD plasmas, while TNT exhibited adduct ions, [TNT-H]-, by using air HCD plasma. In positive ion mode, HMTD gave [HMTD + H]+ m/z 209 ions, while TATP only produced adduct ions with ammonia, [TATP + NH4]+ m/z 240. Regardless of ion source inlet, MA showed protonated molecule ions, [MA + H]+ m/z 150. As analytes were introduced via inlet-1, the stability of the HCD background ion signal reduced, leading to a decrease in sensitivity. Unlike that in negative ion mode, introduction of ambient air in positive ion mode enhanced the sensitivity of the air HCD ion source through the formation of hydronium ions, which gave protonated molecule ions. Ionization mechanisms are also discussed.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Am Soc Mass Spectrom / J. Am. Soc. Mass Spectrom / Journal of the American Society for Mass Spectrometry Year: 2024 Document type: Article Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Am Soc Mass Spectrom / J. Am. Soc. Mass Spectrom / Journal of the American Society for Mass Spectrometry Year: 2024 Document type: Article Country of publication: United States