Your browser doesn't support javascript.
loading
Development of Sensitive In Vitro Protocols for the Biocompatibility Testing of Medical Devices and Pharmaceuticals Intended for Contact with the Eyes: Acute Irritation and Phototoxicity Assessment.
Pôbis, Peter; Kubalcová, Júlia; Milasová, Tatiana; Kandárová, Helena.
Affiliation
  • Pôbis P; Institute of Experimental Pharmacology and Toxicology (IEPT), Centre of Experimental Medicine (CEM), Slovak Academy of Sciences (SAS), Bratislava, Slovakia.
  • Kubalcová J; Institute of Biochemistry and Microbiology, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Bratislava, Slovakia.
  • Milasová T; Institute of Experimental Pharmacology and Toxicology (IEPT), Centre of Experimental Medicine (CEM), Slovak Academy of Sciences (SAS), Bratislava, Slovakia.
  • Kandárová H; Institute of Experimental Pharmacology and Toxicology (IEPT), Centre of Experimental Medicine (CEM), Slovak Academy of Sciences (SAS), Bratislava, Slovakia.
Altern Lab Anim ; 52(5): 261-275, 2024 Sep.
Article in En | MEDLINE | ID: mdl-39168512
ABSTRACT
This study introduces a novel in vitro methodology that employs the 3-D reconstructed tissue model, EpiOcular, to assess the irritation and phototoxicity potential of medical devices and drugs in contact with the eye. Our study evaluated diverse test materials, including medical devices, ophthalmological solutions and an experimental drug (cemtirestat), for their potential to cause eye irritation and phototoxicity. The protocols used in this study with the EpiOcular tissue model were akin to those used in the ultra-mildness testing of cosmetic formulations, which is challenging to predict with standard in vivo rabbit tests. To design these protocols, we leveraged experience gained from the validation project on the EpiDerm skin irritation test for medical devices (ISO 10993-232021) and the OECD TG 498 method for photo-irritation testing. The predictions were based on the tissue viability and inflammatory response, as determined by IL-1α release. By developing and evaluating these protocols for medical devices, we aimed to expand the applicability domain of the tests referred to in ISO 10993-23. This will contribute to the standardisation and cost-effective safety evaluation of ophthalmic products, while reducing reliance on animal testing in this field. The findings obtained from the EpiOcular model in the photo-irritation test could support its implementation in the testing strategies outlined in OECD TG 498.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Eye / Animal Testing Alternatives Limits: Animals / Humans Language: En Journal: Altern Lab Anim Year: 2024 Document type: Article Affiliation country: Slovakia Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Eye / Animal Testing Alternatives Limits: Animals / Humans Language: En Journal: Altern Lab Anim Year: 2024 Document type: Article Affiliation country: Slovakia Country of publication: United kingdom