Harnessing an elastic flow instability to improve the kinetic performance of chromatographic columns.
Gritti, Fabrice; Chen, Emily Y; Datta, Sujit S.
Affiliation
  • Gritti F; Waters Corporation, Instrument/Core Research/Fundamental, 34 Maple Street, Milford, MA, 01757, USA. Electronic address: fabrice_gritti@waters.com.
  • Chen EY; Department of Chemical and Biological Engineering, Princeton University, 41 Olden Street, Princeton, NJ, 08544, USA.
  • Datta SS; Department of Chemical and Biological Engineering, Princeton University, 41 Olden Street, Princeton, NJ, 08544, USA. Electronic address: ssdatta@princeton.edu.
J Chromatogr A ; 1735: 465326, 2024 Oct 25.
Article in En | MEDLINE | ID: mdl-39236358
ABSTRACT
Despite decades of research and development, the optimal efficiency of slurry-packed HPLC columns is still hindered by inherent long-range flow heterogeneity from the wall to the central bulk region of these columns. Here, we show an example of how this issue can be addressed through the straightforward addition of a semidilute amount (500 ppm) of a large, flexible, synthetic polymer (18 MDa partially hydrolyzed polyacrylamide, HPAM) to the mobile phase (1% NaCl aqueous solution, hereafter referred to as "brine") during operation of a 4.6 mm × 300 mm column packed with 10µm BEHTM 125 Å particles. Addition of the polymer imparts elasticity to the mobile phase, causing the flow in the interparticle pore space to become unstable above a threshold flow rate. We verify the development of this elastic flow instability using pressure drop measurements of the friction factor versus Reynolds number. In prior work, we showed that this flow instability is characterized by large spatiotemporal fluctuations in the pore-scale flow velocities that may promote analyte dispersion across the column. Axial dispersion measurements of the quasi non-retained tracer thiourea confirm this possibility they reveal that operating above the onset of the instability improves column efficiency by greater than 100%. These experiments thereby suggest that elastic flow instabilities can be harnessed to mitigate the negative impact of trans-column flow heterogeneities on the efficiency of slurry-packed HPLC columns. While this approach has its own inherent limitations and constraints, our results lay the groundwork for future targeted development of polymers that can impart elasticity when dissolved in commonly used liquid chromatography mobile phases, and can thereby generate elastic flow instabilities to help improve the resolution of HPLC columns.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Acrylic Resins Language: En Journal: J Chromatogr A Year: 2024 Document type: Article Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Acrylic Resins Language: En Journal: J Chromatogr A Year: 2024 Document type: Article Country of publication: Netherlands