Your browser doesn't support javascript.
loading
Knee temperature remains abnormal in patients successfully treated with anterior cruciate ligament reconstruction: An infrared thermography analysis.
De Marziani, Luca; Orazi, Simone; Boffa, Angelo; Andriolo, Luca; Di Martino, Alessandro; Zaffagnini, Stefano; Filardo, Giuseppe.
Affiliation
  • De Marziani L; Clinica Ortopedica e Traumatologica 2 IRCCS Istituto Ortopedico Rizzoli Bologna Italy.
  • Orazi S; Clinica Ortopedica e Traumatologica 2 IRCCS Istituto Ortopedico Rizzoli Bologna Italy.
  • Boffa A; Clinica Ortopedica e Traumatologica 2 IRCCS Istituto Ortopedico Rizzoli Bologna Italy.
  • Andriolo L; Clinica Ortopedica e Traumatologica 2 IRCCS Istituto Ortopedico Rizzoli Bologna Italy.
  • Di Martino A; Clinica Ortopedica e Traumatologica 2 IRCCS Istituto Ortopedico Rizzoli Bologna Italy.
  • Zaffagnini S; Clinica Ortopedica e Traumatologica 2 IRCCS Istituto Ortopedico Rizzoli Bologna Italy.
  • Filardo G; Applied and Translational Research (ATR) Center IRCCS Istituto Ortopedico Rizzoli Bologna Italy.
J Exp Orthop ; 11(3): e70012, 2024 Jul.
Article in En | MEDLINE | ID: mdl-39253542
ABSTRACT

Purpose:

The aim of this study was to evaluate if the operated knee environment remains abnormal in patients successfully treated with anterior cruciate ligament reconstruction (ACL-R).

Methods:

Thirty asymptomatic patients were enrolled (28 men, 2 women, age 28.6 ± 6.54 years, body mass index 24.9 ± 3.0 kg/m2) and evaluated at 42.2 ± 12.5 months after surgery. Patients were assessed with patient-reported outcome measurements and with a triaxial accelerometer. The temperature of the knees as well as four regions of interest were evaluated with an infrared thermographic camera FLIR T1020 (FLIR® Systems) according to a standardised protocol including a baseline evaluation and further evaluations immediately after exercise and after 5, 10 and 20 min. The temperature of the ACL-R knee was compared to that of the contralateral healthy knee for the purpose of the study.

Results:

The mean temperature of the knee was higher (p = 0.010) for the ACL-R knees (31.4 ± 1.4°C) compared to the healthy knees (31.1 ± 1.6°C), as well as for the patellar area (p = 0.005), the lateral area (p = 0.016) and the medial area (p = 0.014). The analysis of the response to the exercises of the ACL-R knees showed similar trends to the healthy knees but higher temperature values at all time points (p < 0.05). Patients who underwent ACL-R with concomitant meniscal treatment showed higher knee temperatures compared to ACL-R knees without concomitant meniscal treatment after 5 (p = 0.047), 10 (p = 0.027) and 20 min (p = 0.048).

Conclusions:

The temperature of asymptomatic knees previously treated with ACL-R is higher than the contralateral healthy knee, both at rest and after exercise, with a further increase in knees that underwent both ACL-R and meniscal treatment. These results suggest an inflammatory state persisting years after the surgery, which could predispose to the early onset of knee degeneration. Level of Evidence III, Case-control study.