Your browser doesn't support javascript.
loading
Fluoride removal using a rotating anode electro-coagulation reactor: Parametric optimization using response surface methodology, isotherms and kinetic studies, economic analysis and sludge characterization.
Meena, Ram Raj; Singh, Raj Mohan; Soni, Pramod; Kumar, Rishi; Kumar, Sushil.
Affiliation
  • Meena RR; Department of Civil Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, 211004, India.
  • Singh RM; Department of Civil Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, 211004, India.
  • Soni P; Department of Civil Engineering, Indian Institute of Technology (BHU), Varanasi, 221005, India.
  • Kumar R; Department of Chemical Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, 211004, India.
  • Kumar S; Department of Chemical Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, 211004, India. Electronic address: sushilk2006@gmail.com.
J Environ Manage ; 370: 122600, 2024 Sep 23.
Article in En | MEDLINE | ID: mdl-39316881
ABSTRACT
The presence of fluoride in drinking water can cause various diseases, such as dental fluorosis and skeletal fluorosis. The present study aims to intensify the fluoride removal using a rotating anode electro-coagulation (EC) reactor with providing the proper hydrodynamics conditions. This fluoride removal is modeled and optimized using Response Surface Methodology (RSM) and central composite design (CCD) with varying operational parameters (rotation speed 20-80 RPM, current 0.2-1.0 A, initial fluoride concentration 8-40 mg/L and time 15-75 min). The maximum fluoride removal is obtained as 96.87% (predicted) and 95.40% (experimental) for the optimized process parameters, initial concentration of 32 mg/L, 0.8 A current, 60 min, and 60 RPM of rotating speed. Kinetic analysis reveals that the removal process adheres to a second-order kinetic model, suggesting that the rate of fluoride removal is dependent on the concentration of fluoride ions present. Isothermal studies indicate that the effective sorption of fluoride onto the generated flocs follows a sips isotherm. The optimal cost analysis is carried out to determine the operational cost as 0.256 USD/m3 for F removal of 93.49% at initial concentration 24 mg/L, time 50 min, current 0.7 A, and rotation 70 rpm and presenting a cost-effective solution for fluoride mitigation. Further, characterizations of the resultant sludge through X-Ray Diffraction (XRD), Fourier-Transform Infrared Spectroscopy (FTIR), and the Toxicity Characteristic Leaching Procedure (TCLP) confirmed the safe disposal potential of the sludge. The findings show a promising approach for fluoride removal, combining high efficiency, economic viability, and environmental safety.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Environ Manage Year: 2024 Document type: Article Affiliation country: India Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Environ Manage Year: 2024 Document type: Article Affiliation country: India Country of publication: United kingdom