Your browser doesn't support javascript.
loading
Multimodal image-guided surgical robot versus 3D-printed template for brachytherapy of malignant tumours in the skull base and deep facial region: a clinical comparative study.
Jin, N; Meng, F; Zhu, L; Xing, L; Lin, Q; Zhang, H.
Affiliation
  • Jin N; Medical School of Chinese PLA, Beijing, China; Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China.
  • Meng F; Medical School of Chinese PLA, Beijing, China; Department of Stomatology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
  • Zhu L; Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China.
  • Xing L; Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China.
  • Lin Q; Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China.
  • Zhang H; Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China. Electronic address: zhanghaizhong@301hospital.com.cn.
Article in En | MEDLINE | ID: mdl-39317561
ABSTRACT
This study compared a multimodal image-guided robot and three-dimensionally (3D) printed templates for implanting iodine-125 (I125) radioactive seeds in patients with malignant tumours in the skull base and deep facial region. Seventeen patients who underwent I125 radioactive seed implantation between December 2018 and December 2019 were included. The operation time, intraoperative blood loss, and accuracy of seed implantation were compared between the multimodal image-guided robot-assisted implantation (experimental) group (n = 7) and 3D-printed template-assisted implantation (control) group (n = 10). In total, 291 seeds were implanted in the experimental group and 436 in the control group; the mean error of seed implantation accuracy was 1.95 ± 0.13 mm and 1.90 ± 0.08 mm, respectively (P = 0.309). The preparation time was 26.13 ± 5.28 min in the experimental group and 0 min in the control group, while the average operation time was 34.44 ± 6.39 min versus 43.70 ± 6.06 min, respectively. The intraoperative blood loss was 4.96 ± 1.76 ml (experimental) versus 8.97 ± 2.99 ml (control) (P = 0.123). Multimodal image-guided robot-assisted I125 radioactive seed implantation met the clinical requirements for treating malignant tumours in the skull base and deep facial regions.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Int J Oral Maxillofac Surg Journal subject: ODONTOLOGIA Year: 2024 Document type: Article Affiliation country: China Country of publication: Denmark

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Int J Oral Maxillofac Surg Journal subject: ODONTOLOGIA Year: 2024 Document type: Article Affiliation country: China Country of publication: Denmark