Your browser doesn't support javascript.
loading
Effect of the BiZact™ Low-Temperature Dissecting Device on Intra- and Postoperative Morbidities Related to Tonsillectomy-A Systematic Review and Meta-Analysis.
Kang, Yun Jin; Stybayeva, Gulnaz; Hwang, Se Hwan.
Affiliation
  • Kang YJ; Department of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University College of Medicine, Cheonan 14584, Republic of Korea.
  • Stybayeva G; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA.
  • Hwang SH; Department of Otolaryngology-Head and Neck Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
Medicina (Kaunas) ; 60(9)2024 Aug 29.
Article in En | MEDLINE | ID: mdl-39336456
ABSTRACT
Background and

Objectives:

We investigated the effects of using a BiZact™ device for tonsillectomy on operating time, intraoperative blood loss, postoperative bleeding rate, and pain through a meta-analysis of the relevant literature. Materials and

Methods:

We reviewed studies retrieved from the databases of PubMed, SCOPUS, Google Scholar, Embase, Web of Science, and Cochrane up to March 2024. The results were analyzed following PRISMA guidelines. Six studies that compared the outcomes of patients receiving perioperative BiZact™ tonsillectomy with those in control groups (cold steel dissection or bipolar tonsillectomy) were included for this analysis of the outcomes, which included intraoperative bleeding and time, postoperative pain, and frequency of postoperative bleeding.

Results:

The operative time (SMD -11.5985, 95%CI [-20.3326; -2.8644], I2 = 99.5%) in the treatment group was significantly reduced compared to the control group. However, BiZact™ showed no significant efficacy in reducing intraoperative bleeding when compared with the control group (SMD -0.0480, 95%CI [-1.8200; 1.7240], I2 = 98.6%). Postoperative pain on day 1 (SMD -0.0885, 95%CI [-0.4368; 0.2598], I2 = 98.9%), day 3 (SMD -0.2118, 95%CI [-0.6110; 0.1873], I2 = 99.5%), and later than day 7 (SMD 0.0924, 95%CI [-0.2491; 0.4338], I2 = 98.6%) in the treatment group was not significantly reduced relative to the control group. When compared to the control group, BiZact™ did not reduce the incidence of secondary postoperative bleeding control in the operation room (OR 0.5711, 95%CI [0.2476; 1.3173], I2 = 32.1%), primary bleeding (OR 0.4514, 95%CI [0.0568; 3.5894], I2 = 0.0%), or all postoperative bleeding events (OR 0.8117, 95%CI [0.5796; 1.1368], I2 = 26.3%).

Conclusions:

This study demonstrated that using the BiZact™ device for tonsillectomy significantly decreased the operative time but could not effectively reduce intraoperative bleeding or postoperative pain and bleeding.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pain, Postoperative / Tonsillectomy Limits: Humans Language: En Journal: Medicina (Kaunas) Journal subject: MEDICINA Year: 2024 Document type: Article Country of publication: Switzerland

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pain, Postoperative / Tonsillectomy Limits: Humans Language: En Journal: Medicina (Kaunas) Journal subject: MEDICINA Year: 2024 Document type: Article Country of publication: Switzerland