Your browser doesn't support javascript.
loading
Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults.
Dunsford, Jack R; Dhaliwal, Jasvir K; Grift, Gracie O; Pryce, Robert; Dominelli, Paolo B; Molgat-Seon, Yannick.
Affiliation
  • Dunsford JR; Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada.
  • Dhaliwal JK; Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada.
  • Grift GO; Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada.
  • Pryce R; Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada.
  • Dominelli PB; Department of Kinesiology and Health Sciences, University of Waterloo, Waterloo, Ontario, Canada.
  • Molgat-Seon Y; Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada.
Physiol Rep ; 12(19): e70068, 2024 Oct.
Article in En | MEDLINE | ID: mdl-39358859
ABSTRACT
We sought to determine the repeatability of EFL in healthy adults during incremental cycle exercise. We hypothesized that the repeatability of EFL would be "strong" when assessed as a binary variable (i.e., absent or present) but "poor" when assessed as a continuous variable (i.e., % tidal volume overlap). Thirty-two healthy adults performed spirometry and an incremental cycle exercise test to exhaustion on two occasions. Standard cardiorespiratory variables were measured at rest and throughout exercise, and EFL was assessed by overlaying tidal expiratory flow-volume and maximal expiratory flow-volume curves. The repeatability of EFL was determined using Cohen's κ for binary assessments of EFL and intraclass correlation (ICC) for continuous measures of EFL. During exercise, n = 12 participants (38%) experienced EFL. At peak exercise, the repeatability of EFL was "minimal" (κ = 0.337, p = 0.145) when assessed as a binary variable and "poor" when measured as a continuous variable (ICC = 0.338, p = 0.025). At matched levels of minute ventilation during high-intensity exercise (i.e., >75% of peak oxygen uptake), the repeatability of EFL was "weak" when measured as a binary variable (κ = 0.474, p = 0.001) and "moderate" when measured as a continuous variable (ICC = 0.603, p < 0.001). Our results highlight the day-to-day variability associated with assessing EFL during exercise in healthy adults.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Exercise / Exercise Test Limits: Adult / Female / Humans / Male Language: En Journal: Physiol Rep Year: 2024 Document type: Article Affiliation country: Canada Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Exercise / Exercise Test Limits: Adult / Female / Humans / Male Language: En Journal: Physiol Rep Year: 2024 Document type: Article Affiliation country: Canada Country of publication: United States