This article is a Preprint
Preprints are preliminary research reports that have not been certified by peer review. They should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Preprints posted online allow authors to receive rapid feedback and the entire scientific community can appraise the work for themselves and respond appropriately. Those comments are posted alongside the preprints for anyone to read them and serve as a post publication assessment.
Interobserver Agreement of Lung Ultrasound Findings of COVID-19
Preprint
in En
| PREPRINT-MEDRXIV
| ID: ppmedrxiv-20176156
ABSTRACT
BackgroundLung ultrasound (LUS) may be used in the diagnostic evaluation of patients with COVID-19. An abnormal LUS is associated with increased risk for ICU admission in COVID-19. Previously described LUS manifestations for COVID-19 include B-lines, consolidations, and pleural thickening. The interrater reliability (IRR) of these findings for COVID-19 is unknown. Research QuestionWhat is the interrater reliability of lung ultrasound findings in patients with RT-PCR confirmed COVID-19? Study Design and MethodsThis study was conducted at conducted at two academic medical centers between 03/2020-06/2020. Nine physicians (hospitalists n=4; emergency medicine n=5) independently evaluated n=20 LUS scans (n=180 independent observations) collected from RTPCR confirmed COVID-19 patients. These studies were randomly selected from an image database consisting of COVID-19 patients evaluated in the emergency department with portable ultrasound devices. Physicians were blinded to any patient information or previous LUS interpretation. Kappa values ({kappa}) were used to calculate IRR. ResultsThere was substantial IRR on the following items normal LUS scan ({kappa}=0.79 [95% CI 0.72-0.87]), presence of B-lines ({kappa}=0.79 [95% CI 0.72-0.87]), >=3 B-lines observed ({kappa}=0.72 [95% CI 0.64-0.79]). Moderate IRR was observed for the presence of any consolidation ({kappa}=0.57 [95% CI 0.50-0.64]), subpleural consolidation ({kappa}=0.49 [95% CI 0.42-0.56]), and presence of effusion ({kappa}=0.49 [95% CI 0.41-0.56]). Fair IRR was observed for pleural thickening ({kappa}=0.23 [95% CI 0.15-0.30]). InterpretationMany LUS manifestations for COVID-19 appear to have moderate to substantial IRR across providers from multiple specialties utilizing differing portable devices. The most reliable LUS findings with COVID-19 may include the presence/count of B-lines or determining if a scan is normal. Clinical protocols for LUS with COVID-19 may require additional observers for the confirmation of less reliable findings such as consolidations. Clinicaltrials.gov Registration NCT04384055 DisclosuresAndre Kumar, MD, MEd is a paid consultant for Vave Health, which manufactures one of the ultrasound devices used in this study. His consultant duties include providing feedback on product development. The other authors do not have any items to disclose.
cc_by_nc_nd
Full text:
1
Collection:
09-preprints
Database:
PREPRINT-MEDRXIV
Type of study:
Experimental_studies
/
Observational_studies
/
Prognostic_studies
/
Rct
Language:
En
Year:
2020
Document type:
Preprint