Your browser doesn't support javascript.
loading
Multi-site Evaluation of SARS-CoV-2 Spike Mutation Detection Using a Multiplex Real-time RT-PCR Assay
Carolin Bier; Anke Edelmann; Kathrin Theil; Rolf Schwarzer; Maria Deichner; Andre Gessner; Andreas Hiergeist; Ute Rentschler; Peter Gohl; Alison Kuchta; Chitra Manohar; Chris Santini; Dana Duncan; Jesse Canchola; Jingtao Sun; Gene Spier; Christian Simon.
Affiliation
  • Carolin Bier; Roche Diagnostics International AG
  • Anke Edelmann; Labor Berlin Charite Vivantes GmbH
  • Kathrin Theil; Labor Berlin Charite Vivantes GmbH
  • Rolf Schwarzer; Labor Berlin Charite Vivantes GmbH
  • Maria Deichner; Institute of Clinical Microbiology and Hygiene, University Hospital Regensburg, Regensburg, Germany
  • Andre Gessner; Institute of Clinical Microbiology and Hygiene, University Hospital Regensburg, Regensburg, Germany
  • Andreas Hiergeist; Institute of Clinical Microbiology and Hygiene, University Hospital Regensburg, Regensburg, Germany
  • Ute Rentschler; Bioscientia
  • Peter Gohl; Bioscientia
  • Alison Kuchta; Roche Molecular Systems, Inc.
  • Chitra Manohar; Roche Molecular Systems, Inc.
  • Chris Santini; Roche Molecular Systems, Inc.
  • Dana Duncan; Roche Molecular Systems, Inc.
  • Jesse Canchola; Roche Molecular Systems, Inc.
  • Jingtao Sun; Roche Molecular Systems, Inc.
  • Gene Spier; Roche Molecular Systems, Inc.
  • Christian Simon; Roche Molecular Systems, Inc.
Preprint in English | medRxiv | ID: ppmedrxiv-21254713
ABSTRACT
BackgroundSARS-CoV-2 causes COVID-19, which can be fatal and is responsible for a global pandemic. Variants with increased transmissibility or the potential to evade immunity have emerged and represent a threat to global pandemic control. Variants of concern (VOC) can be identified by sequencing of viral RNA, or by more rapid methods for detection of subsets of signature mutations. MethodsWe developed a multiplex, real-time RT-PCR assay (cobas(R) SARS-CoV-2 Variant Set 1) for the qualitative detection and differentiation of three key SARS-CoV-2 mutations in the viral spike protein del 69-70, E484K and N501Y. Analytical sensitivity and accuracy were evaluated at three testing sites using clinical specimens from patients infected with SARS-CoV-2 variants belonging to several different lineages, including B.1.1.7, B.1.351, and P.1. ResultsThe limit of detection for E484K was between 180 and 620 IU/mL for the three different isolates tested. For N501Y, the LOD was between 270 and 720 IU/mL (five isolates), while for del 69-70, it was 80 - 92 IU/mL (two isolates). Valid test results were obtained with all clinical specimens that were positive using routine diagnostic tests. Compared to sequencing (Sanger and next-generation), test results were 100% concordant at all three loci; no false positive or false negative results were observed. ConclusionsData collected at three independent laboratories indicates excellent performance and concordance of cobas(R) SARS-CoV-2 Variant Set 1 with sequencing. New sets of primers and probes that target additional loci can be rapidly deployed in response to the identification of other emerging variants.
License
cc_no
Full text: Available Collection: Preprints Database: medRxiv Type of study: Diagnostic study / Experimental_studies / Prognostic study / Qualitative research Language: English Year: 2021 Document type: Preprint
Full text: Available Collection: Preprints Database: medRxiv Type of study: Diagnostic study / Experimental_studies / Prognostic study / Qualitative research Language: English Year: 2021 Document type: Preprint
...