This article is a Preprint
Preprints are preliminary research reports that have not been certified by peer review. They should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Preprints posted online allow authors to receive rapid feedback and the entire scientific community can appraise the work for themselves and respond appropriately. Those comments are posted alongside the preprints for anyone to read them and serve as a post publication assessment.
Investigating sensitivity of nasal or throat (ISNOT): A combination of both swabs increases sensitivity of SARS-CoV-2 rapid antigen tests
Preprint
in English
| medRxiv
| ID: ppmedrxiv-22269426
ABSTRACT
The COVID-19 pandemic has been hallmarked by several waves of variants of concern (VoCs), each with novel challenges. Currently, the highly transmissible Omicron VOC is predominant worldwide, and sore throat is common among other cold-like symptoms. Anecdotes on social media suggested sampling ones throat can increase sensitivity for Omicron detection by antigen-based rapid testing devices (Ag-RDTs). This work determines whether the sensitivity of Ag-RDTs designed for nasal sampling is altered with use of self-administered throat swabs in self-perceived asymptomatic individuals. This investigation compared results of a common Ag-RDT (i.e. Abbott Panbio COVID-19 Ag Rapid Test Device) using three sampling sites nasal swab; throat swab and; combined nasal/throat. All Ag-RDT results were confirmed with molecular testing. Compared to RT-PCR, samples from nasal or throat swabs each detected 64.5% of SARS-CoV-2 cases; however, combining the contributions of each swab increased sensitivity to 88.7%. This trend was also evident with the Rapid Response Ag-RDT (BTNX), which uses a more flexible swabs than Panbio. When nasal swab collection was compared to paired sampling of the nasal/throat using a single swab with the Panbio Ag-RDT, the sensitivity of each was 68.4% and 81.6%, respectively. No false-positive results were observed with nasal, throat, or combined nasal/throat sampling. Self-administered throat and nasal/throat swabs both had >90% acceptability. These findings support the use of self-collected combined nasal/throat sampling for Ag-RDT based SARS-CoV-2 detection in self perceived asymptomatic individuals.
cc_by_nc_nd
Full text:
Available
Collection:
Preprints
Database:
medRxiv
Type of study:
Diagnostic study
Language:
English
Year:
2022
Document type:
Preprint