Study on the usefulness of Direct Saliva sample Collection (DiSC) by polyester swab
Preprint
in English
| medRxiv
| ID: ppmedrxiv-22271529
ABSTRACT
Saliva sample can be self-collected and used in testing of SARS-CoV-2 nucleic acid amplification tests (NAATs) test in Japan. However, this may have difficulty collecting a proper specimen when collecting for the first time. We compared 2 collection methods, conventional methods and Direct Saliva Sample Collection method (DiSC) from 44 asymptomatic or symptomatic individuals who were in quarantine in Toho university hospital. RT-PCR by DiSC method showed about 70 % positive percent agreement compared to RT-PCR by conventional methods. In addition, comparing RT-PCR and TMA by DiSC method, TMA showed about 90 % positive percent agreement compared to RT-PCR. DiSC method is easy to perform by every person, does not have complicated restrictions/instructions and can be used in RT-PCR and TMA. This method allows for ease of saliva collection in certain patient populations.