This article is a Preprint
Preprints are preliminary research reports that have not been certified by peer review. They should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Preprints posted online allow authors to receive rapid feedback and the entire scientific community can appraise the work for themselves and respond appropriately. Those comments are posted alongside the preprints for anyone to read them and serve as a post publication assessment.
Identifying trends in SARS-CoV-2 RNA in wastewater to infer changing COVID-19 incidence: Effect of sampling frequency
Preprint
in English
| medRxiv
| ID: ppmedrxiv-22281667
ABSTRACT
SARS-CoV-2 RNA concentrations in wastewater solids and liquids are correlated with reported incident COVID-19 cases. Reporting of incident COVID-19 cases has changed dramatically with the availability of at-home antigen tests. Wastewater monitoring therefore represents an objective tool for continued monitoring of COVID-19 occurrence. One important use case for wastewater data is identifying when there are sustained changes or trends in SARS-CoV-2 RNA concentrations. Such information can be used to inform public health messaging, testing, and vaccine resources. However, there is limited research on best approaches for identifying trends in wastewater monitoring data. To fill this knowledge gap, we applied three trend analysis methods (relative strength index (RSI), percent change (PC), Mann-Kendall (MK) trend test) to daily measurements of SARS-CoV-2 RNA in wastewater solids from a wastewater treatment plant to characterize trends. Because daily measurements are not common for wastewater monitoring programs, we also conducted a downsampling analysis to determine the minimum sampling frequency necessary to capture the trends identified using the "gold standard" daily data. The PC and MK trend test appear to perform similarly and better than the RSI in terms of early warning signaling for increasing and decreasing trends, so we only considered the PC and MK trend test methods in the downsampling analysis. Using an acceptable sensitivity and specificity cutoff of 0.5, we found that a minimum of 4 samples/week and 5 samples/week is necessary to detect trends identified by daily sampling using the PC and MK trend test method, respectively. If a higher sensitivity and specificity is needed, then more samples per week would be needed. Public health officials can adopt these trend analysis approaches and sampling frequency recommendations to wastewater monitoring programs aimed at providing information on how incident COVID-19 cases are changing in the contributing communities.
cc_by_nc_nd
Full text:
Available
Collection:
Preprints
Database:
medRxiv
Type of study:
Diagnostic study
/
Experimental_studies
/
Observational study
Language:
English
Year:
2022
Document type:
Preprint