Your browser doesn't support javascript.
loading
Avaliação da acuidade visual de recém-nascidos pequenos para a idade gestacional pelos métodos do potencial visual evocado de varredura e cartões de acuidade de Teller / Evaluation of Visual Acuity in Small-for-Gestational-Age Newborns Using Sweep VEP and Teller Acuity Card Methods
São Paulo; s.n; 2008. 110 p.
Thesis in Pt | Tese | ID: pte-45952
Responsible library: BR85.1
Localization: BR85.1; T BF241, F814a, e.1
RESUMO

Objetivo:

Avaliar os efeitos da desnutrição intra-uterina na acuidade visual (AV) de resolução de grades pelo Potencial Visual Evocado de Varredura (PVEv) e Cartões de Acuidade de Teller (CAT).

Método:

Avaliamos a AV de resolução de grades, binocularmente, de 41 recém-nascidos com idade estacional 37 semanas, destes 23 nasceram com o peso adequado para a idade gestacional (AIG - Idade 14,3 ± 7,5 semanas) e 18 nasceram pequenos para a idade gestacional (PIG - Idade 10,7 ± 4,1semanas). A AV foi determinada usando ambas as técnicas psicofísica (CAT) e eletrofisiológica (PVEv). Durante o teste dos CAT foram apresentados cartões contendo em um dos lados grades de ondas quadradas pretas e brancas com freqüência espacial entre 0,23 e 19 ciclos por grau de ângulo visual a 55 cm do participante. O teste iniciou com o cartão com a freqüência espacial mais baixa com orientação randômica desconhecida pelo experimentador. Cartões contendo freqüências espaciais mais altas foram apresentados gradativamente até que uma resposta incorreta ocorresse, então o cartão anterior era apresentado novamente. A AV foi definida pela média aritmética das freqüências espaciais contidas nos cartões para 4 reversões. Para o registro do PVEv, o sistema PowerDiva (Brosnahan et al., 1998) foi usado para gerar todos os estímulos e analisar as repostas provocadas. Estímulos de grades senoidais em reversão de fase em 3, 6 ou 10 Hz foram apresentados em monitor de vídeo monocromático de 21 polegadas com luminância média de 161,13 cd/m2. Registramos o eletroencefalograma com três eletrodos ativos (O1, Oz, O2) relacionados ao eletrodo de referência no vertex. Durante cada tentativa com duração de 10 segundos, resentávamos uma faixa de freqüência espacial que aumentava linearmente. Para cada condição (freqüência temporal - FT) foram usadas no mínimo três tentativas para estimar o limiar...(AU)
ABSTRACT

Objective:

To evaluate the effects of intra-uterine malnutrition on grating visual acuity (VA) using Sweep VEP and Teller Acuity Cards (TAC).

Method:

Binocular grating acuity was evaluated in 41 newborns with gestational age 37 weeks. Twentythree were born with appropriate weight for gestational age (AGA age 14.3 ± 7.5 weeks) and 18 were born small for gestational age (SGA age 10.7 ± 4.1 weeks). Visual acuity was determined using both psychophysical (Teller Acuity Cards) and electrophysiological (sVEP) techniques. For the TAC evaluation, cards having calibrated black and white square waves gratings at spatial frequencies (SFs) between 0.23 and 19 cycles/degree were presented 55 cm from the subject. The test began with the lowest SF card in random orientation to which the experimenter was blind. Subsequent cards were presented in order of increasing SF until an incorrect response was made, at which time the prior (lower-SF) card was presented again. Visual acuity was defined as the average of the SF values for 4 reversals. For the sVEP recordings, the PowerDIVA VEP system (Brosnahan et al., 1998) was used to generate all stimuli and analyze the evoked responses. Stimuli were spatial luminance sinewave gratings presented on a 21-inch monochromatic high-resolution monitor (1600x1200 pixels) with an average luminance of 161.1 cd/m2. Gratings were phase-reversed at either 3, 6 or 10 Hz. The electroencephalogram was recorded using 3 active electrodes (O1,Oz,O2) related to the reference electrode at vertex. During each 10-sec sVEP trial a linear sweep of increasing SF was presented. Sweep ranges were selected according to the subjects age. For each condition (each TF), a minimum of 3 trials were used to estimate thresholds, but the majority of measures were the result of a vector average of 5 to 10 trials. For each condition, the acuity estimate used derived from the...(AU)
Full text: 1 Collection: 06-national / BR Database: Tese Type of study: Clinical_trials Language: Pt Year: 2008 Document type: Thesis Country of publication: Brazil
Full text: 1 Collection: 06-national / BR Database: Tese Type of study: Clinical_trials Language: Pt Year: 2008 Document type: Thesis Country of publication: Brazil