Onlay Patch Coronary Angioplasty with Autologous Saphenous Vein / 대한흉부외과학회지
The Korean Journal of Thoracic and Cardiovascular Surgery
; : 512-517, 2000.
Article
in Korean
| WPRIM (Western Pacific)
| ID: wpr-123606
Responsible library:
WPRO
ABSTRACT
BACKGROUND:
Onlay vein patch coronary angioplasty has been known to be an option for coronary artery stenosis in the selective iesions MATERIAL ANDMETHOD:
During the period between July 1997 and August 1999, coronary angioplasty using autologous saphenous vein was done on 16 sites in 14 cases for the stenotic lesion at the bifurcation area and significantly stenosis distal to anastomosis.RESULT:
Early patency of the angioplasty site was 85.7% at postoperative day 7. There was no statistically difference in graft patency, operative parameters, and complications compared to conventional anatomosis(p>0.05).CONCLUSIONS:
Despite the small number of cases, the patency rate of the coronary patch angioplasty was comparable to the conventional CABG. Coronary artery only patch angioplasty could be performed in highly selected coronary arteries.
Full text:
Available
Database:
WPRIM (Western Pacific)
Main subject:
Saphenous Vein
/
Veins
/
Coronary Artery Bypass
/
Angioplasty
/
Constriction, Pathologic
/
Coronary Vessels
/
Transplants
/
Coronary Stenosis
/
Inlays
Language:
Korean
Journal:
The Korean Journal of Thoracic and Cardiovascular Surgery
Year:
2000
Document type:
Article