Anesthetic management for Liver transplantatin : 4 cases / 대한마취과학회지
Korean Journal of Anesthesiology
; : 1021-1028, 1993.
Article
in Korean
| WPRIM (Western Pacific)
| ID: wpr-154726
Responsible library:
WPRO
ABSTRACT
We managed four cases of anesthesia for liver transplantation from August, 1992 to January, 1993. Four recipients, all male patients and ages of 40th, were suffered from liver cirrhosis related to Chronic hepatitis B and one recipient (case 1) was diagnosed as combined hepatocellular carcinoma. Operation risks by Pugh's classification were 10 (case 1), 8 (case 2), 7 (case 3) and 12 (case 4). Duaration of anesthesia was in the range of 13 to 22.5 hours. Various hemodynamic monitorings were observed and anesthetic managements were uneveritful. C.O., SVR, temperature and coagulation factors were analyzed. 2 patients (case 1 & 4) were expired due to acute rejection (case 1) and primary non-function of the grafted liver (case 4) postoperatively.
Full text:
Available
Database:
WPRIM (Western Pacific)
Main subject:
Blood Coagulation Factors
/
Liver Transplantation
/
Classification
/
Carcinoma, Hepatocellular
/
Hepatitis B, Chronic
/
Transplants
/
Hemodynamics
/
Anesthesia
/
Liver
/
Liver Cirrhosis
Limits:
Humans
/
Male
Language:
Korean
Journal:
Korean Journal of Anesthesiology
Year:
1993
Document type:
Article