ABSTRACT
OBJECTIVES:
The purpose of this study was to evaluate curing degree of three dual-cure resin cements with the elapsed time in self-cure and dual-cure mode by means of the repeated measure of micro-hardness. MATERIALS ANDMETHODS:
Two dual-cure self-adhesive resin cements studied were Maxcem Elite (Kerr), Rely-X Unicem (3M ESPE) and one conventional dual-cure resin cement was Rely-X ARC resin cement (3M ESPE). Twenty specimens for each cements were made in Teflon mould and divided equally by self-cure and dual-cure mode and left in dark, 36degrees C, 100% relative humidity conditional-micro-hardness was measured at 10 min, 30 min, 1 hr, 3 hr, 6 hr, 12 hr and 24 hr after baseline. The results of micro-hardness value were statistically analyzed using independent samples t-test and one-way ANOVA with multiple comparisons using Scheffe's test.RESULTS:
The micro-hardness values were increased with time in every test groups. Dual-cure mode obtained higher micro-hardness value than self-cure mode except after one hour of Maxcem. Self-cured Rely-X Unicem showed lowest value and dual-cured Rely-X Unicem showed highest value in every measuring time.CONCLUSIONS:
Sufficient light curing to dual-cure resin cements should provided for achieve maximum curing.
Full text:
Available
Database:
WPRIM (Western Pacific)
Main subject:
Polytetrafluoroethylene
/
Resin Cements
/
Humidity
/
Light
Language:
Korean
Journal:
Journal of Korean Academy of Conservative Dentistry
Year:
2011
Document type:
Article