Your browser doesn't support javascript.
loading
A study on the vertical augmentation of the alveolar ridge by distraction osteogenesis in dogs / 대한치과보철학회지
Article in Ko | WPRIM | ID: wpr-218245
Responsible library: WPRO
ABSTRACT
STATEMENT OF PROBLEM: Implant-type distractor uses a removable distraction device that has an appearance similar to that of a dental implant and utilizes many of the same techniques for placement as are used for dental implants. MATERIAL AND METHOD: In this study, 48 implant type titanium distractors were inserted into the osteotomized alveolar bone of 12 beagle dogs. After a 7-day latency period, the alveolar bone was augmented by 5mm vertically at a rate of 1.0 mm/day. The dogs were sacrificed after 4weeks, 8weeks and 12 weeks for radiographic, histologic, and histomorphometric analysis. RESULTS: Copper equivalent value showed significant difference between 4 weeks and the other weeks(8, 12 weeks)(p<0.05). But there was no significant difference between maxillary and mandibular groups. In the bone to metal contact analysis, there was a significant difference between 4 weeks and 12 weeks(p<0.05). On the contrary, there was no significant difference between maxilla and mandible. The bone area showed significantly higher values in 12 weeks compared to 4 weeks(p<0.05). Histologically mineralization began at the host bone margins. At 12 weeks, increasing accumulation of Ca++ element was confirmed. CONCLUSION: From the results above, the new bone formation was increased according to consolidation period. Especially there was significant difference between 4 weeks and 12 weeks(p<0.05). Implant type distractors used in this study to augment vertical ridge defect may prove to be a clinically useful treatment option in selected cases.
Subject(s)
Key words
Full text: 1 Database: WPRIM Main subject: Osteogenesis / Titanium / Dental Implants / Copper / Osteogenesis, Distraction / Alveolar Process / Latency Period, Psychological / Mandible / Maxilla Limits: Animals Language: Ko Journal: The Journal of Korean Academy of Prosthodontics Year: 2007 Document type: Article
Full text: 1 Database: WPRIM Main subject: Osteogenesis / Titanium / Dental Implants / Copper / Osteogenesis, Distraction / Alveolar Process / Latency Period, Psychological / Mandible / Maxilla Limits: Animals Language: Ko Journal: The Journal of Korean Academy of Prosthodontics Year: 2007 Document type: Article