A simulative biomechanical experiment on different position of none-cement acetabular components influencing the load distribution around acetabulum / 生物医学工程学杂志
Journal of Biomedical Engineering
; (6): 97-100, 2008.
Article
in Chinese
| WPRIM (Western Pacific)
| ID: wpr-230647
Responsible library:
WPRO
ABSTRACT
In the present study, a three dimensional finite-element model of the human pelvic was reconstructed, and then, under different acetabular component position (the abduction angle ranges from 30 degrees to 70 degrees and the anteversion ranges from 5 degrees to 30degrees) the load distribution around the acetabular was evaluated by the computer biomechanical analysis program (Solidworks). Through the obtained load distribution results, the most even and reasonable range of the distribution was selected; therefore the safe range of the acetabular component implantation can be validated from the biomechanics aspect.
Full text:
Available
Database:
WPRIM (Western Pacific)
Main subject:
Pelvis
/
Physiology
/
Stress, Mechanical
/
Biomechanical Phenomena
/
Computer Simulation
/
Cadaver
/
Diagnostic Imaging
/
Range of Motion, Articular
/
Computer-Aided Design
/
Arthroplasty, Replacement, Hip
Type of study:
Diagnostic study
Limits:
Humans
Language:
Chinese
Journal:
Journal of Biomedical Engineering
Year:
2008
Document type: