Your browser doesn't support javascript.
loading
Improved gastric lavage with close system
Article in Vietnamese | WPRIM (Western Pacific) | ID: wpr-2500
Responsible library: WPRO
ABSTRACT

Method:

73 patients were performed gastric lavage by an improved technique with new equipment. All of the patients were monitored clinical signs (pulse rate, blood pressure, respiratory rate, SpO2, lung sound...) and tested (blood count, electrolyte, ECG, chest X-ray, toxic screening...) before and after doing gastric lavage. The results were compared to a retrospective study in 1998-2000 we found that complications are reduced significantly from 6.21% to 2.74%. In addition, there was not any severity complication; we only met two cases hypokalemia after doing gastric lavage.

Conclusion:

the improved technique with new equipment of gastric lavage would be safe for the patients, reduce significantly complication, and easy to implement.
Subject(s)

Full text: Available Database: WPRIM (Western Pacific) Main subject: Emergencies / Gastric Lavage Type of study: Observational study Language: Vietnamese Journal: Journal of Medical Research Year: 2002 Document type: Article
Full text: Available Database: WPRIM (Western Pacific) Main subject: Emergencies / Gastric Lavage Type of study: Observational study Language: Vietnamese Journal: Journal of Medical Research Year: 2002 Document type: Article
...