Repair the infra-orbital defect with a rotation flap after basal cell carcinoma resection / 中华整形外科杂志
Article in Zh | WPRIM | ID: wpr-292112
Responsible library: WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To explore the method repairing the infra-orbital defect after basal cell carcinoma resection.</p><p><b>METHOD</b>A facial rotation flap was applied to repair the infra-orbital defects from tumor resection in 28 cases.</p><p><b>RESULT</b>All defects were repaired by this one-stage method, which avoided skin graft, shortened the operation time and minimized the operation trauma. The incision sears are inconspicuous. The facial contours are more satisfactory.</p><p><b>CONCLUSION</b>This technique is simple and effective in repairing the infra-orbital defects, worthy of extensive application.</p>
Subject(s)
Full text: 1 Database: WPRIM Main subject: Orbit / Rotation / Skin Neoplasms / General Surgery / Surgical Flaps / Carcinoma, Basal Cell Limits: Aged / Female / Humans / Male Language: Zh Journal: Chinese Journal of Plastic Surgery Year: 2002 Document type: Article